11. Safety devices
Type of
protection
Protection form
Model
AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE
Circuit
protection
Current fuse (PCB*)
250 V, 20 A
250 V, 3.15 A 250 V, 5 A
Fan motor
protection
Terminal
protection
program
Activate
100±15°C
Fan motor stop
150±15°C
Fan motor stop
Reset
95±10°C
Fan motor restart
120±15°C
Fan motor
restart
Compressor
protection
Terminal
protection
program
(Discharge
temp.)
Activate
110°C
Compressor stop
Reset
After 7 minutes
Compressor restart
- 51 -