03-07
-30.0
-25.0
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
95.57
68.89
50.31
37.19
27.81
21.02
16.05
12.38
9.63
7.56
5.98
4.77
3.84
3.11
2.53
2.08
1.71
1.42
1.19
1.00
0.84
0.71
0.61
0.24
0.32
0.43
0.57
0.73
0.92
1.14
1.39
1.65
1.93
2.21
2.49
2.77
3.02
3.26
3.48
3.67
3.85
4.00
4.13
4.25
4.35
4.43
Outdoor heat exchanger thermistor
Voltage(V)Resistance(K )Tempe C
-30.0
-25.0
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
94.26
67.95
49.62
36.68
27.42
20.73
15.83
12.21
9.50
7.46
5.90
4.71
3.78
3.06
2.50
2.05
1.69
1.40
1.17
0.98
0.83
0.70
0.60
0.51
0.44
0.08
0.11
0.15
0.20
0.26
0.34
0.43
0.55
0.68
0.84
1.01
1.21
1.42
1.64
1.88
2.11
2.35
2.58
2.81
3.02
3.22
3.41
3.57
3.73
3.87
Heat sink thermistor
Voltage(V)Resistance(K )Tempe C
-30.0
-25.0
-20.0
-15.0
-10.0
-5.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
200.20
144.32
105.38
77.90
58.25
44.03
33.62
25.92
20.17
15.84
12.54
10.00
8.04
6.51
5.30
4.35
3.59
2.98
2.49
2.09
1.76
1.49
1.27
0.80
1.05
1.33
1.65
1.98
2.33
2.66
2.98
3.27
3.54
3.77
3.96
4.13
4.27
4.39
4.49
4.57
4.64
4.70
4.74
4.78
4.81
4.84
Outdoor Temprature thermistor