- 51 -
OUTDOOR UNIT
AOGA30-60F
1. Specifications
Type
Cooling only
Model name AOGA30FBTAS
Power supply 220—240 V ~ 50 Hz
Available voltage range 198—264 V
Starting current A 60
Fan
Airflow rate Cooling
m
3
/h
4400—4400
Type × Q'ty Propeller × 1
Motor output W 95
Sound pressure level *1 Cooling dB(A) 56—57
Heat exchanger type
Dimensions (H × W ×
D)
mm
main: 882 × 955 × 36.4sub: 882 × 570 × 18.2
Fin pitch 1.45
Rows × Stages main: 2 × 42sub: 1 × 42
Pipe type Copper
Fin
Type (Material) Corrugate (Aluminum)
Surface treatment Corrosion resistance (Blue fin)
Compressor
Type × Q'ty Scroll × 1
Motor output W 1950
Refrigerant
Type R410A
Factory charge g 2500
Refrigerant oil
Type POE
Amount
cm
3
858
Enclosure
Material Steel
Color
Beige
Approximate color of MUNSELL 10YR7.5/1.0
Dimensions
(H × W × D)
Net
mm
914 × 970 × 370
Gross 1048 × 1064 × 479
Weight
Net
kg
77
Gross 85
Connection pipe
Size
Liquid
mm (in)
Ø 9.52 (Ø 3/8)
Gas Ø 15.88 (Ø 5/8)
Method Flare
Pre-charge length
m
7.5
Max. length 30
Max. height difference 15
Operation range Cooling °C 21 to 52
NOTES:
Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Pipe length: 7.5 m, Height difference: 0 m.
Protective function might work when using it outside the operation range.
*1: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.