- (02 - 10) -
OUTDOOR UNIT
AOGA18-25FBTAH
OUTDOOR UNIT
AOGA18-25FBTAH
ADDITIONAL CHARGE CALCULATION6.
MODEL
: AOGA18FBTAH
Refrigerant Charge
z
MODEL
: AOGA25FBTAH
Refrigerant Charge
z
Refrigerant type R410A
Refrigerant amount g 1,500
Total pipe length m 7.5 or less 15 20(Max.)
20 g/m
Additional charge g 0 150 250
Refrigerant type R410A
Refrigerant amount g 1,800
Total pipe length m 7.5 or less 10 15 20 25 (Max.)
20g/m
Additional charge g 0 50 150 250 350