02 - 15
)
-
OUTDOOR UNIT
AOTG09-22LV
OUTDOOR UNIT
AOTG09-22LV
MODEL
: AOTG18LV
Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.994 0.979
10 - - 1.012 0.994 0.979
7.5 - 1.000 1.012 0.994 0.979
5 0.969 1.000 1.012 0.994 0.979
0 0.969 1.000 1.012 0.994 0.979
2
Indoor unit is
under than
outdoor unit.
-5 0.964 0.995 1.007 0.989 0.974
-7.5 - 0.993 1.004 0.986 0.972
-10 - - 1.002 0.984 0.969
-15 - - - 0.974 0.959
COOLING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.951 0.950
10 - - 0.979 0.967 0.966
7.5 - 0.988 0.983 0.971 0.970
5 0.994 0.992 0.987 0.975 0.974
0 1.002 1.000 0.995 0.983 0.982
2
Indoor unit is
under than
outdoor unit.
-5 1.002 1.000 0.995 0.983 0.982
-7.5 - 1.000 0.995 0.983 0.982
-10 - - 0.995 0.983 0.982
-15 - - - 0.983 0.982