OUTDOOR UNIT
AOTG09-22LV
OUTDOOR UNIT
AOTG09-22LV
MODEL
:AOTG22LV
Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.974 0.955
10 - - 0.997 0.974 0.955
7.5 - 1.000 0.997 0.974 0.955
5 0.995 1.000 0.997 0.974 0.955
0 0.995 1.000 0.997 0.974 0.955
2
Indoor unit is
under than
outdoor unit.
-5 0.990 0.995 0.992 0.969 0.950
-7.5 - 0.993 0.990 0.966 0.948
-10 - - 0.987 0.964 0.945
-15 - - - 0.954 0.936
COOLING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.946 0.953
10 - - 0.977 0.962 0.968
7.5 - 0.988 0.981 0.966 0.972
5 0.998 0.992 0.985 0.970 0.976
0 1.006 1.000 0.993 0.977 0.984
2
Indoor unit is
under than
outdoor unit.
-5 1.006 1.000 0.993 0.977 0.984
-7.5 - 1.000 0.993 0.977 0.984
-10 - - 0.993 0.977 0.984
-15 - - - 0.977 0.984