EasyManua.ls Logo

Fujitsu ASTG09LVCC - Page 50

Fujitsu ASTG09LVCC
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-
(
02 - 16
)
-
OUTDOOR UNIT
AOTG09-22LV
OUTDOOR UNIT
AOTG09-22LV
MODEL
:AOTG22LV
Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.974 0.955
10 - - 0.997 0.974 0.955
7.5 - 1.000 0.997 0.974 0.955
5 0.995 1.000 0.997 0.974 0.955
0 0.995 1.000 0.997 0.974 0.955
2
Indoor unit is
under than
outdoor unit.
-5 0.990 0.995 0.992 0.969 0.950
-7.5 - 0.993 0.990 0.966 0.948
-10 - - 0.987 0.964 0.945
-15 - - - 0.954 0.936
COOLING
Pipe length (m)
57.5101520
Height
difference H
(m)
1
Indoor unit is
upper than
outdoor unit.
15 - - - 0.946 0.953
10 - - 0.977 0.962 0.968
7.5 - 0.988 0.981 0.966 0.972
5 0.998 0.992 0.985 0.970 0.976
0 1.006 1.000 0.993 0.977 0.984
2
Indoor unit is
under than
outdoor unit.
-5 1.006 1.000 0.993 0.977 0.984
-7.5 - 1.000 0.993 0.977 0.984
-10 - - 0.993 0.977 0.984
-15 - - - 0.977 0.984

Related product manuals