Chapter 4 Setting the Backup Software
4.5 NetVault
FUJITSU Storage ETERNUS LT20 S2/LT40 S2/LT60 S2 Tape Library User’s Guide -Server Connection-
Copyright 2021 FUJITSU LIMITED P3AM-5322-12ENZ0
64
9 Click the [Cleaning] tab in the [Configure Device] page that appears, set the following Cleaning
items, and click the [OK] button.
Automatic Cleaning Supported: on (the default setting is "on")
Barcode Prefix(es) of cleaning media: set the label string of the cleaning cartridge.
Cleaning Slots: set the slot number that contains the cleaning cartridge.
The following is a settings example with a label string of "CLN" and a slot number of "5".
10 Click the [OK] button to go back to the [Edit Device] page and then click the [Save] button at the
bottom right of the page.
11 In the [Manage Devices] page of the WebUI, click the [Manage Library] button of the target
library to switch to the [Tape Library Management] page.
Reboot the LT20 S2/LT40 S2/LT60 S2 by clicking the [Restart] button at the bottom right of the
page.
The new settings are applied after the LT20 S2/LT40 S2/LT60 S2 is rebooted.
End of procedure