3 Adjust the offset/vertical magnification as necessary.
Offset Setting Description
Unit Select [ADF (front)] or [ADF (back)] as the target
for offset adjustment.
Note that when the connection is via VRS board
(optional), you can only adjust the offset for [ADF
(back)].
Main Adjusts the horizontal (width) offset.
The setting range is from -2 to 3 mm in 0.5 mm
increments.
Sub Adjusts the vertical (length) offset.
The setting range is from -2 to 3 mm in 0.5 mm
increments.
Vertical magnification
Adjustment
Description
Unit The target for vertical
magnification adjustment is fixed
at [ADF].
Vertical magnification
Adjustment (length)
Adjusts the vertical (length)
magnification.
The setting range is from -3.1 to
3.1% in 0.1% increments.