Specifications
(*9) 1 MB = 1,048,576 bytes.
2.1.3 Environmental specifications
Table 2.3 lists environmental and power requirements.
Table 2.3 Environmental/Power requirements
Specification
Item
MBC2073RC MBC2036RC
Operating 5 to 55 °C
Non-operating –40 to 70 °C
Transport –40 to 70 °C
DE surface temperature at operating 5 to 60 °C
Temperature
(*1)
Gradient 20 °C/h or less
Operating 5 to 95 %RH
Non operating 5 to 95 %RH
Transport 5 to 95 %RH
Relative
humidity
Maximum wet bulb temperature 29 °C (no condensation)
Operating (*3) 0.6 mm (5 to 20Hz) / 9.8 m/s
2
(1G) (20 to 300Hz) or less
Non-operating (*4) 3.1 mm (5 to 20Hz) / 49m/s
2
(5G) (20 to 300Hz) or less
Vibration
(*2)
Transport (packaged) 3.1 mm (5 to 20Hz) / 49m/s
2
(5G) (20 to 300Hz) or less
Operating 980 m/s
2
(100G) / 1 ms duration
Non-operating 3,920 m/s
2
(400G) / 1 ms duration
Shock (*2)
Transport (packaged) 3,920 m/s
2
(400G) / 1 ms duration
Operating –305 to +3,048 m (–1,000 to +10,000 feet)
Altitude
Non-operating –305 to +12,192 m (–1,000 to +40,000 feet)
Regulation ±5%
Ready (average) 0.23A 0.2A
Spin up
1.2A (peak)
1.5A (less than 100µs)
Peak operating current
Maximum (peak) DC
(*6)
1.2A
+12V DC
Peak operating current
DC (reference) (*6)
0.36A 0.33A
Regulation ±5%
Ready (average) 0.5A
Peak operating current
Maximum (peak) DC
(*6)
1.2A
+5V DC
Peak operating current
DC (reference) (*6)
0.75A
Power
requirement
(*5)
Ripple (+5V, +12V) 250mVp-p or less (*7)
24 C141-E266