RX100 S7 Operating Manual 49
Hardware installation
5.2 Installing/removing the server in/from the
rack
V CAUTION!
● Please observe the safety information and notes on rack mounting in
chapter "Important information" on page 33.
● At least two people are needed to install / remove the server in the
rack. (For the Japanese market, please refer to " 安全上の注意 ".)
● The rack may tip over if more than one unit is removed at the same
time.
● The server may not occupy the top height unit of the rack
(38HU/42HU PRIMECENTER Rack, DataCenter Rack,
19-inch standard rack (for the Japanese market)),
as otherwise boards cannot be replaced even with the plug-in module
fully extended.
V CAUTION!
The server does not have cable management in the rack.
Before removal, all cables connected to the server must be removed
from the sockets. Proceed as follows:
● Exit all applications and shut down the operating system properly.
● Switch off the server.
● Disconnect and remove all cables connected to the server.
● Remove the server.