56 Operating Manual RX100 S7
Hardware installation
5.3.1 Connecting the monitor
Ê Plug the data cable for the monitor into the video connector on the server
(item 5 in figure 4 on page 55).
Ê Connect the insulated connector on the monitor power cable to a grounded
outlet in the rack's socket strip (see also the technical manual for the rack).
5.4 Connecting the server to the mains
In its basic configuration the server has a permanently installed power supply
unit or a hot-plug power supply unit. Besides the hot-plug power supply unit, a
second hot-plug power supply unit can be installed optionally to serve as a
redundant power supply. If one power supply unit fails, the second power supply
unit in the redundant configuration ensures operation can continue
uninterrupted.
V CAUTION!
The server is automatically set to a mains voltage in the range 100 V -
127 V or 200 V - 240 V. You may only operate the server if its rated
voltage range corresponds to the local mains voltage.
Ê Connect the power cord to the server power supply unit.
Ê Connect the mains connector to an outlet on the rack's socket strip.
I For details, please see the technical manual for the rack.