Periphery ETERNUS LT40 S2 tape library
U41861-J-Z126-1-76 51
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
Dokuschablonen 19x24 Version 7.4us für FrameMaker V7.x vom 09.02.2010 © cognitas GmbH 2001-2010
29. June 2015 Stand 16:47.07 Pfad: P:\FTS-BS\Server\SE-Server\SE-Doku\1303909_BA_Additional\prod_e\ba_addon.k05
4.2.6.2 Device settings
The device settings are defined by Customer Support. The sections below provide infor-
mation on how you can change these settings.
If you wish to make any changes to the configuration, you should consult Customer
Support, who will ensure that the functionality of the device is retained in BS2000 operation.
Configuring the LAN connection
You configure the LAN connection of the tape library using the OCP:
Ê Select the OCP menu Configuration > Network.
Ê Configure the following parameters in the order specified:
1. DHCP - No DHCP (a static IP address is recommended)
2. (Static) IP address
3. Network mask
4. Gateway address
After you have completed network configuration, you should reboot the tape library (by
switching the device off and on). The RMU can then be accessed via the configured IP
address.
Settings for operation with BS2000
You must specify the following settings for operation with BS2000:
Ê Select Configuration > Library in the OCP menu or Configuration > System.via the RMU