Split system (Single phase and 3-phase type)
Maintenance Document 1544-1 93
6 Disassembly Process of Outdoor Unit
> Warning ! <
Before servicing the unit, turn the power supply
switch OFF, then, do not touch electric parts for
10 minutes due to the risk of electric shock.
6.1 Single phase type
6.1.1 Appearance
6.1.2 Service panel removal
6.1.3 Top panel removal
Screw
serrated
Hook (3 places)
Remove the mounting screws.
Remove the SERVICE PANEL
by sliding downward.
Screw
(with washer)
Remove the mounting screws
Screw
(with washer)
Screw
(serrated)
Remove the TOP PANEL
Single Phase type