0 = Off
1 = Heating
2 = Cooling
19.PARAMETER TABLE
24:00
1.7.5.x.15 to 1.7.5.x.20 Address of digital output 01-06:
Digital output address 01-06 linked to the individual pressure switch.
1.7.5.x.21 Low pressure alarm:
Enables the alarm indication when the pressure is lower than the configured value.
1.7.5.x.22 High pressure alarm:
Enables the alarm indication when the pressure is higher than the configured value.
1.7.5.x.23 Alarm hysteresis:
Hysteresis of pressure alarms.
1.7.5.x.24 Minimum time between activations:
The function applies to the main control outputs of the individual pressure switches and is the minimum time between two actuations of the main digital
outputs. This time guarantees that simultaneous activation of the digital outputs will not occur, avoiding surges in the supply network and excessive
fluctuations in the control variable.
1.7.5.x.25 Minimum output time on:
Minimum output time on/off.
1.7.6 Individual thermostat:
The letter x represents individual thermostats 1 to 3.
1.7.6.x.1 Operation mode:
Configures the Operation Mode.
1.7.6.x.2 Temperature setpoint:
Output temperature setpoint
1.7.6.x.3 Temperature hysteresis:
Temperature control hysteresis linked to individual thermostat output.
1.7.6.x.4 Low pressur alarm:
Enables the alarm indication when the temperature is lower than the configured value.
1.7.6.x.5 High pressure alarm:
Enables the alarm indication when the temperature is higher than the configured value.
Feature
Minimum
Maximum Unit
Standard
Description
1.7.6.x.1
1.7.6.x.7
1.7.6.x.2
1.7.6.x.8
1.7.6.x.3
1.7.6.x.9
1.7.6.x.4
1.7.6.x.10
200,0 (39,2)
0 02
*
*
1
20,0 (68,0)
-50,1 (-58,2)
-50,0 (-58,0)
0
°C (°F)
°C (°F)
°C (°F)
-
°C (°F)
-
-
°C (°F)
-
1,0 (1,8)
0
0
1.7.6.x.5
1.7.6.x.6
1,0 (1,8)
-50,0 (-58,0)
0
5,0 (9,0)
-50,1 (-58,2)
200,1 (392,2)
5,0 (9,0)
0
5,0 (9,0)
200,0 (392,0)
200,1 (392,2)
5,0 (9,0)
3
Temperature setpoint
Linked pressure switch
Hysteresis of alarms
Low temperature alarm
Operation mode
High temperature alarm
Temperature hysteresis
Temperature sensor
Main output
Contact type: NO-NC (main)
24:00
24:00
1.7.6.x.19
1.7.6.x.14
1.7.6.x.20
1.7.6.x.15
1.7.6.x.21
1.7.6.x.16
*
0 24:00 Min
Min
Min
°C (F)
-
24:00
24:00
9999 sec
1 -
1.7.6.x.13
0 30 Min
Min
Min
0 240 Min
Min
-
9999
9999
00:00
00:00
00:00
00:00
00:00
00:00
1.7.6.x.17
1.7.6.x.11
1.7.6.x.18
1.7.6.x.12
0
0
0
0
0
0
1
0
0
Defrost time 6
Defrost time 5
Defrost time 1
Defrost time 3
Defrost time 4
Defrost time 2
Defrost output
Minimum time output on / off
Interval between defrosts
Defrost length
Contact type: NO-NC (defrost)
66

Table of Contents

Other manuals for Full Gauge Controls RCK-862 plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Full Gauge Controls RCK-862 plus and is the answer not in the manual?

Full Gauge Controls RCK-862 plus Specifications

General IconGeneral
BrandFull Gauge Controls
ModelRCK-862 plus
CategoryController
LanguageEnglish

Related product manuals