1. MOUNTING
1-12
14. Apply Three Bond to the thread part of hex. bolt (15) with seal washer (16) and
use them to fasten the transducer. Check that the fore mark on the shaft is aligned
with the projection at the bottom of the transducer.
15. Pass the flat washer (8), gasket (7), washer (8), and the gland (19) onto the trans-
ducer cable.
16. Fasten the gland (19) to the top of the shaft (5).
17. Apply Kinoruster to both sides of the gasket2 (18), and put it on the gate valve
(20).
18. Put the shaft on the gasket2 (18), and align the hollow side on the flange (3) with
the projection of the transducer (1).
19. Remove the M8 hex. bolt (13) and M8 spring washer (14) from the lock ring to free
the shaft (5).
The fore mark on the shaft
Align them.
The projection on the transducer
Bottom view
Gland (19)
Flat washer (8)
Gasket (7)
Flat washer (8)
The projection on the transducer (1)
Flange (4)
Hex. nut (15)(M4x16)
Seal washer (16)(M4)
Apply Liquid Gasket (TB1121) here.
The fore mark on the shaft
Check that they