2. WIRING
2-12
Signal cable (from distributor unit): Connect the power and signal lines, and fix the
cable on the conductive tape with the clamp in the transceiver unit. Then tighten the
cable with the SC lock.
Transducer cable: Connect the signal and shield lines, and fix the cable on the con-
ductive tape with the clamp in the transceiver unit. Then tighten the cable with the
SC lock.
2.6 Junction Box (option)
The transducer cable is connected to the junction box with an extension cable. After
making the connection, seal the cable gland with putty for watertightness.
2.6.1 How to fabricate the cable
Before cable fabrication, attach the cable glands and gaskets which are attached at
the cable entrance on the cable in advance. Please pay attention to the orientation of
cable glands and gaskets on the cable.
Transducer
cable
Signal cable
(From distributor unit)
Shield
Clamp Clamp
SC lock SC lock
Terminal for power
Inner sheath
Inner sheath
Cut to suitable length
considering location on
terminal board.
Insulation tube
FV2-P4
FV5.5-5
FV1.25-4
To internal earth stud
Vinyl tape
See interconnection
diagram.
Gland
Gasket