2. WIRING
2-2
2.2 Precautions for Cable Installation
To avoid noise and interference, lay cables between units as far away as possible
from power cables and radio transmission signal cables.
When the cables run in parallel with power cables, separate them 400 mm at mini-
mum.
Run the transducer cables separate from other cables as much as possible.
Also, ground the equipment to prevent electrical shock and mutual interference.
2.2.1 WAGO connection
For the display unit, the terminal opener is included inside the cable clamp on the back
cover.
For the distributor unit, the two terminal openers are included inside the unit. Check
that the size (large or small) of the opener is correct before use.
2.3 Display Unit
2.3.1 How to fabricate the cables
Using the supplied terminals on the inside of the DS-8500, fit the drain wire (or shield
line) of each cable with a terminal, then attach the terminal to the inside of the DS-8500
(the same place it was situated originally).
TTYCSLA-4
Procedure
1. Twist the cores.
2. Push the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
Push downward.
Terminal opener
WAGO connector
Wire
Twist
6
Drain wireDrain wire
130130
8080
Pass the heat shrinkable tube
(local supply) onto the drain wire.
Vinyl tape
Armor Inner sheath
Clamp here with cable clamp.