3. SETTINGS AND STATUS
3-4
For the PC, click [Open] of [Alert Log] to show the alerts that occurred in the past (max.
20 alerts).
[Time [UTC]]: Shows the time and date when the alert occurred.
[Alert]: Shows the alert message.
[Reason]: Shows the reason why the alert occurred.
Click [Screenshot] to take a screenshot.
For the alert lists, see page AP-4.
3.4 IO Monitor
The data input from each port can be monitored.
Note: This menu appears only on the PC.
[Port]: Select the port that displays the received data.
[Start]: Click to start the receiving data display. The display shows a maximum of
10,000 characters. The [Start] button changes to the [Stop] button.
[Stop]: Click to stop the receiving data display. The [Stop] button changes to the
[Start] button.
01/JAN/2020 18:30
01/JAN/2020 18:31
01/JAN/2020 18:32
01/JAN/2020 18:35
01/JAN/2020 18:37
Display area of receiving data
Character
count