1.4 List of Functions
1-24
Table 1.4.1 (5/5) List of Functions
Function Description Remarks
Alarm
GUARD ALARM/TIMER ALARM/
GURAD ZONE/LOST TRGT/CPA LIMIT/
AUTO ACQ TRGT FULL/
MAN ACQ TRGT FULL/
ARPA SYSTEM ERROR/
AZIMATH/HEAD LINE/TRIGGER/
VIDEO/GYRO/LOG/EPFS/XTE/ARRIVAL/
WPT/DEPTH/OPERATOR FITNESS/
SYSTEM ERROR/KEYBOARD ERROR
- Visible and Audible alarm
- The output for external alarm
can be selected by [Menu] ->3
-> 6 to 9.
Antenna height set 5/7.5/10/15/20/25/30/35/40/45/50 m or more
Near range STC set Selecting curve: 2/2.5/3/3.5
Middle range
STC set
Selecting curve: 3/4/5/6
Far range STC set Selecting curve: 6/7/8
Sea conditions set 1/2/3/4/5
STC operating
range set
+
10
Cable Attenuation
correction
Auto/Manual
Tuning initialize
Auto/Manual
MBS adjustment 0 to 255
Radar display/
Monitor display
Selection: MAIN/SUB
Demo Mode OFF/EG/SPU/PC
SPU and PC:
FURUNO development
Type of Mode IMO/A/B/C/W Selected when installing.
Switching of Model Available (X-band and S- band/Output power) Selected when factory setting.
Wheel direction Forward/Backward
Software Ver-up
- Processor unit: SPU board
1. Mini-card on SPU board
2. RS-232C
- TR unit: RFC board
Via Processor unit as the mentioned above
(RS-232C)
- Control unit:
Only factory is available.
Note:
See chapter 4 for details of setting radar type IMO/A/B/C/W.