4.7 Setting of AD-100 or GC-10
4-44
4.7.1 Setting List
Table 4.7.3(1/2) Setting List
In the factory setting, all the DIP switches are set to OFF and jumpers are set to #1 except that JP1 is set
to #1, #2 and #3.
Segment Setting contents Setting conditions
SW 1
SW1-#1, #2, #3 Ratio
SW1-#1 #2 #3
OFF OFF OFF 360 x
ON OFF OFF 180 x
OFF ON OFF 90 x
ON ON OFF 36 x
SW1-#4, #5, #6 Gyro type
SW1-#4 #5 #6
OFF OFF OFF AC synchrous
OFF OFF OFF DC synchrous
ON OFF OFF DC step system
OFF ON OFF Full-wave pulsating current
ON ON OFF Half-wave pulsating current
SW1-#7, #8 Frequency
SW1-#7 #8
OFF OFF 50/60 Hz
ON OFF 400 Hz
OFF ON 500 Hz
ON ON DC
SW 2
SW2-#1 Rotor voltage
SW2-#1
ON 20 VAC to 45 VAC
OFF 30 VAC to 70 VAC
ON 40 VAC to 90 VAC
OFF 60 VAC to 135 VAC
SW2-#2, #3 Stator voltage
SW2-#2 #3
ON OFF 20 VAC to 45 VAC
OFF OFF 30 VAC to 70 VAC
ON OFF 40 VAC to 90 VAC
OFF OFF 60 VAC to 135 VAC
ON OFF 20 VDC to 60 VDC
OFF OFF 40 VDC to 100 VDC
SW2-#4 Self test
SW2-#4
ON: Self-test “YES”
OFF:Self- test “NO”
SW2-#5, #6
(See Table 4.7.4)
NMEA output interval
setting and output
sentence/Baud rate.
SW2-#5 #6 Interval Sentence
OFF OFF 1 s HDTVHW
ON OFF 200 ms HDT
OFF ON 100 ms HDT
ON ON 25 ms HDT
*The baud rate is determined according to the setting of
SW3-#2.
SW2-#7
Detection of “Stator”
disconnection
-OFF: Enable (When detected, AD outputs stop on 25 ms
interval only.)
- ON: Disable
SW2-#8 CPU reset Reset by switching ON -> OFF.