EasyManua.ls Logo

Furuno FAR-2137S - Page 246

Furuno FAR-2137S
563 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.7 Setting of AD-100 or GC-10
4-43
Table 4.7.2 Overview of Factory Setting
*” Ver” represents the version of the program.
Item Factory setting Recommended setting
Gyro type AC synchro
Excitation frequency 50/60 Hz
Rotor voltage 60 VAC to 135 VAC
Stator voltage 60 VAC to 135 VAC
Ratio 360x
Supply voltage
30 VAC to 135 VAC
40 VDC to 100 VDC
Make the setting according
to the connected gyro.
NMEA output
- NMEA Ver : 1.5
- Baud rate : 4800 bps
- Talker name* : AG (Ver-03, 04)
: HE (Ver-05)
- Interval : 1 second
- Sentence : HDTVHW
When NMEA is used,
- NMEA Ver-2.0
- 38,400 bps
- Output
interval 25 ms
Self-test (Enable) Do not do self test (Disable) Set whichever desired
AD format data
transmission interval
- J7, 8, 9 25 ms
- J10, 11, 12 200 ms
Use at 25 ms
Ver-05
AD-100: Enable
GC: Disable
Set as Disable
Power-off function*
This function is not
available for Ver-03 and 04.
Enable (Ver-03, 04)
(AD data is not output when the
disconnection of “Stator” is detected.
the only 25 ms AD format data .)
Detection of “Stator”
disconnection
Enable (Ver-05)
(When the disconnection of “Stator”
is detected, all AD output data are
stopped.)
Set as “Enable”
Note:
When the GC board of the Ver-05 is incorporated in RPU-013, and the power-off function is set to
“Enable” and when power-off is detected, all the output data are stopped. When this happens, set
the HDG value in the [HDG] box menu again.
How to Check the Program Number
A label showing the specification is attached onto U1 of the GC board. You can
check the program number from the suffix of the marking.
U1 Program Ver
64S4097-0 Ver-03
64S4097-1 Ver-04
64S4097-2 Ver-05

Table of Contents

Other manuals for Furuno FAR-2137S

Related product manuals