Appendix 2) Specifications
AP2-3
5. POWER SUPPLY
1. Display unit 24 VDC or 115/230 VAC, 1ø, 50/60 Hz
FAR-21x7: 24 VDC, 2.3 A; 100-230 VAC, 0.7A (100 V)
FAR-28x7: 24 VDC, 3.2 A; 100-230 VAC, 0.9 A (100 V)
440 VAC, 1 ø, 50/60 Hz with optional transformer RU-1803
2. Processor unit FAR-2117/2817/2117-BB:
24VDC: 7.6A
1
/8.5A
2
, 100-115 VAC: 2.6A
1
/3.0A
2
,
220-230 VAC: 1.6A
1
/1.7A
2
FAR-2127/2827/2127-BB:
24 VDC: 8.8A
1
/9.7A
2
, 100-115 VAC: 3.0A
1
/3.4A
2
,
220-230 VAC: 1.8A
1
/1.9A
2
1:
24 rpm,
2:
42 rpm
3. Antenna unit (S-band) 200/220/380/440 VAC
115/230 VAC, 1ø, 50 or 60 Hz
Antenna voltage input (100 kt)
Model
- 200 VAC,
ø3, 50 Hz,
- 220 VAC,
ø3, 60 Hz
- 380 VAC,
ø3, 50 Hz,
- 440 VAC,
ø3, 60 Hz
- 220 VAC,
ø3, 50 Hz,
(HSC)
- 220 VAC,
ø3, 60 Hz
(HSC)
- 220 VAC,
ø3, 60 Hz
(HSC)
FAR-2137S(BB) 3.0 A 1.5 A 3.5 A 3.5 A 1.7 A
FAR-2837S 3.0 A 1.5 A 3.5 A 3.5 A 1.7 A
FAR-2837SW 3.0 A 1.5 A - - -
FAR-2137SW 3.0 A 1.5 A 3.5 A 3.5 A 1.7A
4. Console 115/230 VAC, 1ø, 50/60 Hz, 440 VAC, 1ø, 50/60 Hz with
optional transformer RU-1803
6. ENVIRONMENTAL CONDITIONS
1. Ambient temperature (Complies with IEC 60945)
Indoor units -15°C to +55°C
Antenna unit -25°C to +55°C (storage +70°C)
2. Relative humidity 95% at 40°C
3. Waterproofing Antenna unit: IPX6 (IEC 60529)
Indoor units: IPX0 (IEC 60529)
4. EMC Full compliance with IEC 60945 Ed. 4
(to 2 GHz cabinet radiation)