2. WIRING
15
6. Set the DIP switch on MAIN board 12P1000 referring to the descriptions below.
7. Connect ground wires with the pre-
attached crimp-on lugs shown
right. The cables that require
grounding are shown in the column
"Grounding" in the table at the top
of this page.
8. Refasten the cable entrance as-
sembly.
Cable entrance No. Cable
Connector
(on 12P1000)
Grounding
1: For ship’s mains DPYC-1.5 CN1
—
2: For display unit (power) CN4
3: LAN for INS or PC
(Recording software)
DTI-C5E350
VCV (φ13.5 mm)
Note: Do not use
other cable.
CN5
4: For external equipment TTYCSLA-1 CN6, CN7,
CN9
Needed
5: For display unit (signal) TTYCSLA-4 CN8
6: For matching box DPYCYSLA-2.5 CN2, CN3
7: For display unit
(RD-20 or RD-50)
TTYCSLA-4 CN12, CN13
8: For BAM CN10
9: For BAM TTYCSLA-1 CN14
10: For transceiver unit
(No. 2)
TTYCSLA-4 CN11
DIP SW Function
1 1: ON (Restore default settings.)
0: OFF (Default setting, for normal use)
Note: When FE-800
starts up with “ON”, The
“FA” mark appears at the
top-left corner of the
screen.
2 1: ON (Start the transceiver unit indepen-
dently.)
0: OFF (Default setting, for normal use)
3 1: ON (Don’t back up settings.)
0: OFF (Default setting, for normal use)
4 Turn output to port 2 of IF-2503 [ON] or [OFF]. [ON] outputs a con-
tact signal when the Depth-below-Keel alarm occurs.
5 Turn output to port 3 of IF-2503 [ON] or [OFF]. [ON] outputs a con-
tact signal when any of the following errors occur.
• Bottom lost
• TX Volt Error
• TCVR High Temperature
6 to 8 No use.
DIP switchDIP switch