38
Direct Mode Functions

5. To adjust the CH3 up side,
set the CH3 dial to full up
(100%) and adjust the rate
with the + and - keys.
Setting range; 0~100%
- Return to the initial value (100%) by pressing the + and - keys
simultaneously for about one second.
100%
6. At the end of adjustment,
press the DIRECT key twice.
(Returns to the initial screen.)
- 2 times
Maximum travel
The CH3 ATV determines the CH3 maximum servo travel. However, when the func-
tions below are adjusted, the maximum travel may exceed the limit set by the ATV.
Be sure to inspect you linkage installation after any adjustment is made.
- CH3 subtrim
- Programmable mixing (When CH3 is set to the slave side.)
- Tilt mixing
Note
When the CH3 servo travel is insufficient even when ATV was increased to DOWN
100% and UP 100%, the travel can be increased somewhat by using programmable
mixing. (See Page 84.)