EasyManua.ls Logo

Future Design FDC-8300 - Ordering Code

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories
CT94-1 = 0 - 50 Amp. AC Current TransformerCT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3 = Isolated4-20m
A/0-20mAAnalog Output ModuleOM95-3 = Isolated 4 - 20 mA / 0 - 20 mA Analog Output Module
OM95-4 = Isolated1-5V/0-5
VAnalog Output ModuleOM95-4 = Isolated 1 - 5V / 0 - 5V Analog Output Module
OM95-5 = Isolated 0
- 10V Analog Output ModuleOM95-5 = Isolated 0 - 10V Analog Output Module
OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )
DC94-1 = Isolated 20V / 25mA DC Output Power SupplyDC94-1 = Isolated 20V / 25mA DC Output Power Supply
DC94-2 = Isolated 12V / 40mA DC Output Power SupplyDC94-2 = Isolated 12V / 40mA DC Output Power Supply
DC94-3 = Isolated 5V / 80mA DC Output Power SupplyDC94-3 = Isolated 5V / 80mA DC Output Power Supply
CM94-1 = Isolated RS-485 Interface ModuleCM94-1 = Isolated RS-485 Interface Module
CM94-2 = Isolated RS-232 Interface ModuleCM94-2 = Isolated RS-232 Interface Module
CM94-3 = Isolated4-2
0m
A/0-20mARetransmission ModuleCM94-3 = Isolated 4 - 20 mA / 0 - 20 mA Retransmission Module
CM94-4 = Isolated1-5V/0-5
VRetransmission ModuleCM94-4 = Isolated 1 - 5V / 0 - 5V Retransmission Module
CM94-5 = Isolated 0
- 10V Retransmission ModuleCM94-5 = Isolated 0 - 10V Retransmission Module
CC94-1 = RS-232 Interface Cable (2M)CC94-1 = RS-232 Interface Cable (2M)
Um8300 = FDC-8300 User's ManualUm8300 = FDC-8300 User's Manual
Power InputPower Input
4: 90 - 264 VAC, 50/60 HZ
5: 11 - 26 VAC or VDC
9: Special Order
4: 90 - 264 VAC, 50/60 HZ
5: 11 - 26 VAC or VDC
9: Special Order
1: Standard Input1: Standard Input
Input
1 - Universal InputInput 1 - Universal Input
Thermocouple:
J, K, T, E, B,Thermocouple: J, K, T, E, B,
R, S, N, LR, S, N, L
RTD: PT100 DIN, PT100 JISRTD: PT100 DIN, PT100 JIS
Current:
4 - 20mA,0-2
0mA.Current: 4 - 20mA, 0 - 20 mA.
Voltage:0-1V
,0-5V,1-5V,Voltage: 0 - 1V, 0 - 5V, 1 - 5V,
0 - 10V0 - 10V
Input2-C
TandAnalog InputInput 2 - CT and Analog Input
C
T:0-50Amp. AC
CurrentCT: 0 - 50 Amp. AC Current
Transformer
Analog Input
:4-20mA,Analog Input: 4 - 20 mA,
0 - 20mA,0-1
V
,0-5V,0 - 20mA, 0 - 1V, 0 - 5V,
1-5V,0-10V.1 - 5V, 0 - 10V.
Input
3 - Event Input ( EI )Input 3 - Event Input ( EI )
9:
Special Order9: Special Order
Signal InputSignal Input
0: None0: None
1: Relay Form A1: Relay Form A
2A/240VAC
2:
P
ulsed voltage to2: Pulsed voltage to
drive SSR, 5V/30mAdrive SSR, 5V/30mA
3: Isolated3: Isolated
4-20mA/0-20mA4 - 20mA / 0 - 20mA
4: Isolated1-5
V/0-5
V4: Isolated 1 - 5V / 0 - 5V
5: Isolated0-10
V5: Isolated 0 - 10V
6: Triac Output6: Triac Output
1A / 240VAC,SSR1A / 240VAC,SSR
9: Special order9: Special order
Output 1Output 1
9: Special order9: Special order
1: Relay Form C1: Relay Form C
0: None0: None
1 2
3 4
5
7
FDC-8300 -FDC-8300 -
1 2 Ordering Code1 2 Ordering Code
Standard Model:Standard Model:
FDC-8300-41111010
90 - 264 operating voltage90 - 264 operating voltage
Input: Standard InputInput: Standard Input
Output 1: RelayOutput 1: Relay
Output 2: RelayOutput 2: Relay
Alarm 1: Form A RelayAlarm 1: Form A Relay
RS- 485 Communication InterfaceRS- 485 Communication Interface
Example
*
*
2A / 240VAC2A / 240VAC
Alarm 1Alarm 1
0: None
1: RS-485
2: RS-232
3: Retransmit 4-20mA/0-20mA
4: Retransmit1-5V/0-5V
5: Retransmit0-10V
9: Special order
0: None
1: RS-485
2: RS-232
3: Retransmit 4-20mA/0-20mA
4: Retransmit 1 - 5V / 0 - 5V
5: Retransmit 0 - 10V
9: Special order
Communications
*
*
0: None0: None
1: Relay Form A 2A/240VAC1: Relay Form A 2A/240VAC
2: Pulsed voltage to2: Pulsed voltage to
drive SSR, 5V / 30mAdrive SSR, 5V / 30mA
3: Isolated4-20mA/0-20mA3: Isolated 4 - 20mA / 0 - 20mA
4: Isolated1-5V/0-5V4: Isolated 1 - 5V / 0 - 5V
5: Isolated0-10V5: Isolated 0 - 10V
6: Triac Output, 1A / 240VAC, SSR6: Triac Output, 1A / 240VAC, SSR
7: Isolated 20V / 25mA DC7: Isolated 20V / 25mA DC
Output Power SupplyOutput Power Supply
8: Isolated 12V / 40 mA DC8: Isolated 12V / 40 mA DC
Output Power SupplyOutput Power Supply
9: Isolated 5V / 80mA DC9: Isolated 5V / 80mA DC
Output Power SupplyOutput Power Supply
A: Special orderA: Special order
Output 2Output 2
Range set by front keyboard
Need to order an accessory CT94-1 if
Heater Break detection is required.
Range set by front keyboard
Need to order an accessory CT94-1 if
Heater Break detection is required.
*
*
*
SNA10B = Smart Network Adaptor for FD-Net
Software, Converts 255 channels
of RS-485 or RS-422 to RS-232
Network
SNA10B = Smart Network Adaptor for FD-Net
Software, Converts 255 channels
of RS-485 or RS-422 to RS-232
Network
P10A = Hand-held Programmer for FDC
Series Controller
P10A = Hand-held Programmer for FDC
Series Controller
SNA10A = Smart Network Adaptor for Third
Party Software, Converts 255
channels of RS-485 or RS-422 to
RS-232 Network
SNA10A = Smart Network Adaptor for Third
Party Software, Converts 255
channels of RS-485 or RS-422 to
RS-232 Network
Related ProductsRelated Products
UMA83001A-August-2024
4
6
8
9: Special order9: Special order
2A / 240VAC2A / 240VAC
1: Relay Form A1: Relay Form A
0: None0: None
Alarm 2Alarm 2
Options
0: None0: None
Alarm 2: Form A RelayAlarm 2: Form A Relay
Options: NoneOptions: None
**
**