Accessories
CT94-1 = 0 - 50 Amp. AC Current TransformerCT94-1 = 0 - 50 Amp. AC Current Transformer
OM95-3 = Isolated4-20m
A/0-20mAAnalog Output ModuleOM95-3 = Isolated 4 - 20 mA / 0 - 20 mA Analog Output Module
OM95-4 = Isolated1-5V/0-5
VAnalog Output ModuleOM95-4 = Isolated 1 - 5V / 0 - 5V Analog Output Module
OM95-5 = Isolated 0
- 10V Analog Output ModuleOM95-5 = Isolated 0 - 10V Analog Output Module
OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )OM94-6 = Isolated 1A / 240VAC Triac Output Module ( SSR )
DC94-1 = Isolated 20V / 25mA DC Output Power SupplyDC94-1 = Isolated 20V / 25mA DC Output Power Supply
DC94-2 = Isolated 12V / 40mA DC Output Power SupplyDC94-2 = Isolated 12V / 40mA DC Output Power Supply
DC94-3 = Isolated 5V / 80mA DC Output Power SupplyDC94-3 = Isolated 5V / 80mA DC Output Power Supply
CM94-1 = Isolated RS-485 Interface ModuleCM94-1 = Isolated RS-485 Interface Module
CM94-2 = Isolated RS-232 Interface ModuleCM94-2 = Isolated RS-232 Interface Module
CM94-3 = Isolated4-2
0m
A/0-20mARetransmission ModuleCM94-3 = Isolated 4 - 20 mA / 0 - 20 mA Retransmission Module
CM94-4 = Isolated1-5V/0-5
VRetransmission ModuleCM94-4 = Isolated 1 - 5V / 0 - 5V Retransmission Module
CM94-5 = Isolated 0
- 10V Retransmission ModuleCM94-5 = Isolated 0 - 10V Retransmission Module
CC94-1 = RS-232 Interface Cable (2M)CC94-1 = RS-232 Interface Cable (2M)
Um8300 = FDC-8300 User's ManualUm8300 = FDC-8300 User's Manual
Power InputPower Input
4: 90 - 264 VAC, 50/60 HZ
5: 11 - 26 VAC or VDC
9: Special Order
4: 90 - 264 VAC, 50/60 HZ
5: 11 - 26 VAC or VDC
9: Special Order
1: Standard Input1: Standard Input
Input
1 - Universal InputInput 1 - Universal Input
Thermocouple:
J, K, T, E, B,Thermocouple: J, K, T, E, B,
R, S, N, LR, S, N, L
RTD: PT100 DIN, PT100 JISRTD: PT100 DIN, PT100 JIS
Current:
4 - 20mA,0-2
0mA.Current: 4 - 20mA, 0 - 20 mA.
Voltage:0-1V
,0-5V,1-5V,Voltage: 0 - 1V, 0 - 5V, 1 - 5V,
0 - 10V0 - 10V
Input2-C
TandAnalog InputInput 2 - CT and Analog Input
C
T:0-50Amp. AC
CurrentCT: 0 - 50 Amp. AC Current
Transformer
Analog Input
:4-20mA,Analog Input: 4 - 20 mA,
0 - 20mA,0-1
V
,0-5V,0 - 20mA, 0 - 1V, 0 - 5V,
1-5V,0-10V.1 - 5V, 0 - 10V.
Input
3 - Event Input ( EI )Input 3 - Event Input ( EI )
9:
Special Order9: Special Order
Signal InputSignal Input
0: None0: None
1: Relay Form A1: Relay Form A
2A/240VAC
2:
P
ulsed voltage to2: Pulsed voltage to
drive SSR, 5V/30mAdrive SSR, 5V/30mA
3: Isolated3: Isolated
4-20mA/0-20mA4 - 20mA / 0 - 20mA
4: Isolated1-5
V/0-5
V4: Isolated 1 - 5V / 0 - 5V
5: Isolated0-10
V5: Isolated 0 - 10V
6: Triac Output6: Triac Output
1A / 240VAC,SSR1A / 240VAC,SSR
9: Special order9: Special order
Output 1Output 1
9: Special order9: Special order
1: Relay Form C1: Relay Form C
0: None0: None
1 2
3 4
5
7
FDC-8300 -FDC-8300 -
1 2 Ordering Code1 2 Ordering Code
Standard Model:Standard Model:
FDC-8300-41111010
90 - 264 operating voltage90 - 264 operating voltage
Input: Standard InputInput: Standard Input
Output 1: RelayOutput 1: Relay
Output 2: RelayOutput 2: Relay
Alarm 1: Form A RelayAlarm 1: Form A Relay
RS- 485 Communication InterfaceRS- 485 Communication Interface
Example
*
*
2A / 240VAC2A / 240VAC
Alarm 1Alarm 1
0: None
1: RS-485
2: RS-232
3: Retransmit 4-20mA/0-20mA
4: Retransmit1-5V/0-5V
5: Retransmit0-10V
9: Special order
0: None
1: RS-485
2: RS-232
3: Retransmit 4-20mA/0-20mA
4: Retransmit 1 - 5V / 0 - 5V
5: Retransmit 0 - 10V
9: Special order
Communications
*
*
0: None0: None
1: Relay Form A 2A/240VAC1: Relay Form A 2A/240VAC
2: Pulsed voltage to2: Pulsed voltage to
drive SSR, 5V / 30mAdrive SSR, 5V / 30mA
3: Isolated4-20mA/0-20mA3: Isolated 4 - 20mA / 0 - 20mA
4: Isolated1-5V/0-5V4: Isolated 1 - 5V / 0 - 5V
5: Isolated0-10V5: Isolated 0 - 10V
6: Triac Output, 1A / 240VAC, SSR6: Triac Output, 1A / 240VAC, SSR
7: Isolated 20V / 25mA DC7: Isolated 20V / 25mA DC
Output Power SupplyOutput Power Supply
8: Isolated 12V / 40 mA DC8: Isolated 12V / 40 mA DC
Output Power SupplyOutput Power Supply
9: Isolated 5V / 80mA DC9: Isolated 5V / 80mA DC
Output Power SupplyOutput Power Supply
A: Special orderA: Special order
Output 2Output 2
Range set by front keyboard
Need to order an accessory CT94-1 if
Heater Break detection is required.
Range set by front keyboard
Need to order an accessory CT94-1 if
Heater Break detection is required.
*
*
*
SNA10B = Smart Network Adaptor for FD-Net
Software, Converts 255 channels
of RS-485 or RS-422 to RS-232
Network
SNA10B = Smart Network Adaptor for FD-Net
Software, Converts 255 channels
of RS-485 or RS-422 to RS-232
Network
P10A = Hand-held Programmer for FDC
Series Controller
P10A = Hand-held Programmer for FDC
Series Controller
SNA10A = Smart Network Adaptor for Third
Party Software, Converts 255
channels of RS-485 or RS-422 to
RS-232 Network
SNA10A = Smart Network Adaptor for Third
Party Software, Converts 255
channels of RS-485 or RS-422 to
RS-232 Network
Related ProductsRelated Products
UMA83001A-August-2024
4
6
8
9: Special order9: Special order
2A / 240VAC2A / 240VAC
1: Relay Form A1: Relay Form A
0: None0: None
Alarm 2Alarm 2
Options
0: None0: None
Alarm 2: Form A RelayAlarm 2: Form A Relay