G.Weike Laser
Profession Laser Manufacturer more than 15 Years.
12
Picture 3-2 Installation location drawing
Caution:Be careful of the sharpen edges of the packages and edges of the
machine.
3.3.1 Ground requirements
1) The ground where install the equipment should be flat .The laser, bed and
the working area height difference should not exceed 10 mm. The place where
not flat must use the adjustment mat iron to leveling.
2) Lathe bed and table leg of the entire installation surface thickness of
concrete is not less than 200 mm, crushing strength shall not be less than
30N/mm
2
, load is greater than 30 KN/m
2
.
3) The entire installation surface of the fuselage must be consists of a smooth
continuous slab within the scope of every supporting points .New floor/pressure
plate must be avoided this case such as the weather is dry, the floor/pressure
appears cracks beyond the following values. Do not allow the changes caused
by machine’s tilt make the travel range of laser beam on the lens more than 0.5
mm.
3.3.2 Environmental requirements
1) Environment temperature
When operating machine, environment temperature must be between + 10
and + 33 . In machine shutdown, the ambient temperature of installation
site shall not be reduced to + 4 below.
Caution: To avoid hot deformation because of the sun shining when installed
near the window position, please fitted with shutters to avoid these situations.
Please put the gas tank in the shade place .As the high pressure of the gas
pressure gas tanks have explosive properties in higher temperature
surroundings.
2) Outside air
In order to not affect emission quality, so much, must ensure that installation
location hasn't been able to absorption wavelength of laser is 1.06 µm ray
particles or material. Such as paint sends out a steam containing solvents, or
steam from oil removal device.
3) Laser resistant device
When environment temperature is 35
to 43
, equipment must assemble
laser resistant device (such as air conditioning, etc.
4) Control system
s cooling
Control system’s cooling depends on the closed control system internal air
circulation within the enclosure .Thus ensure the parts maximize not
contaminated with dust and dirt .Wet room is not suitable for control system
running, especially contactor and relay contact will corrosion, resulting in control
system failure .The humidity environment must less than 70%
3.3.3 Vibration requirement
Due to a change in the load of the equipment surrounding area caused by
the external function will affect the workpiece cutting quality. For example: