57
Chart 6-2
Picture 6-1
Clockwise the drain switch to discharge the waste water.
Picture 6-2
Dismantle the air filter as the direction shown on the machine see picture 6-2.
Every 3 month
1 .Check the electric parts (such as switches,
terminal blocks, etc.), with a clean dry cloth to
wipe.
Caution: Make sure the power is off when check
the electric parts. Any problems, please contact
with professional person to solve the problems.
To ensure the electric
parts surface is clean,
cold water to lengthen
service life
2.Replacement of circulating water (distilled
water) and cleaning tank and metal filter; If with
ROFIN laser, cooling water can be half a year after
adding the corrosion inhibitor to replace a cooling
water, if the PRC lasers, add the propylene glycol
cooling water can be half a year after the
replacement of cooling water at a time
To
ensure normal
operation of the laser
★★
Matters needing attention
Long-term outage when required
A
.
Place the cold water machine and the pipe away from the dust.
B
.
Will the power cord to pull away from the socket, will clean the power cord;
C.Cleaning unit ontology: the units inside, please do not let the water splash on the
electronic parts;
D.The water completely ruled out.