GALaxy eHydro Elevator Controller Section 7 Main CPU Adjustable Variables
7-9
Table 7-3: Car Options
Field Variable
Min
Max
Initial
Units
Arrival Lant
0
1
0
-
Arrival Lantern.
1 = Activate lant/gong without onward call
Behnd CC Canc
0
1
0
-
Behind Car Call Cancel. When enabled the elevator
will not latch any car calls in the opposite direction of
travel.
Cab Lant Ctrl
0
2
0
-
Cab Lantern Control. The default is for the cab
lanterns to go off when the door is fully open. This
allows the cab lanterns to go off earlier.
+1 = Ring cab lanterns as soon as door starts to open
+2 = Ring the cab lanterns when the door reaches
DPM point.
ClGate NoPref
0
1
0
-
Close Gate (Swing Door) When No Onward
Preference. The gate on a swing door normally stays
open until a call is placed. This bit causes the gate to
close while the car is sitting at the floor.
COP/Remote
CC
0
7
0
-
COP/Remote Car Call Select.
0 = Both COP and Remote Car Call Station used to
enter calls.
1 = Separate: COP only or Remote CC only used to
enter car calls.
+2 = C-R: Car calls entered on the COP sets the
acknowledgment light on the Remote station.
+4 = R-C: Car calls entered on the Remote station sets
the acknowledgment light on the COP.
COP/RM Dis
0
14
0
-
COP/Remote Disable.
+1 = Up Direction Disable COP,
+2 = Down Direction Disable COP,
+4 = Up Direction Disable Remote Panel,
+8 = Down Direction Disable Remote Panel
DCB Canc Dwll
0
1
0
-
Door Close Button Cancel Dwell Time. When this
parameter is set to 1 we do not allow DCB to cancel
the door dwell time. This basically disables DCB to
shorten door dwell time.