4.2.- FITTING OF CONTROL INSTRUMENTS AND SERVOLUBRICATOR4.2.- FITTING OF CONTROL INSTRUMENTS AND SERVOLUBRICATOR
Connect control instruments as per Connect control instruments as per installation scheme. Fit the push-button valveinstallation scheme. Fit the push-button valve V”V” at a maximum distance oat a maximum distance o
5 metre from the 5 metre from the starter and use flexible pipe of starter and use flexible pipe of 2.5 mm inner diameter for connection. If the 2.5 mm inner diameter for connection. If the control pipe has tocontrol pipe has to
be longer, fit a be longer, fit a solenoid valve near the starter and connect same with an electrical remote control valve. solenoid valve near the starter and connect same with an electrical remote control valve. In thisIn this
case it is case it is recommendrecommended using a starter equipped with a ed using a starter equipped with a GALI starting limiter.GALI starting limiter.
In installation comprising automatic starting and engine control equipment, the push-button valveIn installation comprising automatic starting and engine control equipment, the push-button valve V”V” can becan be
replace by a solenoid valve.replace by a solenoid valve.
Fit the Fit the servolubricatoservolubricatorr
S”S”
vertically in vertically in a well visible and practicable place to a well visible and practicable place to allow for easy priming, control andallow for easy priming, control and
refilling.refilling.
4.3. - SUPPLY OF COMPRESSED AIR
4.3. - SUPPLY OF COMPRESSED AIR
The starter is designed to deliver its The starter is designed to deliver its maximum torque at 30 bar, although this pressure will not maximum torque at 30 bar, although this pressure will not always bealways be
necessary to carry out start-up. necessary to carry out start-up. The minimum pressure necessary to achieve motor start-up will depend on eachThe minimum pressure necessary to achieve motor start-up will depend on each
specific application. GALI guaranteespecific application. GALI guarantees that all s that all A45 starters carry out A45 starters carry out the meshing movementhe meshing movement and main valvet and main valve
opening at least up to 8 bar.opening at least up to 8 bar.
In no case should the In no case should the starter be subjected to pressures greater than 30 bar.starter be subjected to pressures greater than 30 bar.