FLIGHT MANAGEMENT
SYSTEM
OVERVIEW
FLIGHT
INSTRUMENTS
EIS
AUDIO PANEL
& CNS
FLIGHT
MANAGEMENT
HAZARD
AVOIDANCE
AFCS
ADDITIONAL
FEATURES
APPENDICES INDEX
HSI Annunciation Description Example on HSI
LNAV RNAV GPS approach using published LNAV
minima
Approach Service Level
- LNAV, LNAV+V, L/VNAV, LP, LP+V, LPV
LNAV+V RNAV GPS approach using published LNAV
minima. Advisory vertical guidance is provided
L/VNAV
(available only if
SBAS available)
RNAV GPS approach using published LNAV/
VNAV minima (downgrades to LNAV if SBAS
unavailable)
LP
(available only if
SBAS available)
RNAV GPS approach using published LP minima
(downgrades to LNAV if SBAS unavailable)
LP+V
(available only if
SBAS available)
RNAV GPS approach using published LP minima
Advisory vertical guidance is provided
(downgrades to LNAV if SBAS unavailable)
LPV
(available only if
SBAS available)
RNAV GPS approach using published LPV
minima
Table 5-9 Approach Types
LOADING AN APPROACH INTO THE ACTIVE FLIGHT PLAN
Loading an approach into the active flight plan using the PROC Key:
1) Press the PROC Key. The Procedures Window is displayed.
2) Highlight ‘SELECT APPROACH’, and press the ENT Key. The Approach Loading Page is displayed.
3) Select the airport and approach:
a) Use the FMS Knob to select an airport and press the ENT Key.
b) Select an approach from the list and press the ENT Key.
Or:
a) If necessary, push the FMS Knob to exit the approach list, and use the large FMS Knob to move the cursor to
the APPROACH CHANNEL field.
b) Use the FMS Knob to enter the approach channel number, and press the ENT Key to accept the approach
channel number. The airport and approach are selected.
4) Select a transition (if required) and press the ENT Key.
5) Minimums
a) To set ‘MINIMUMS’, turn the small FMS Knob to select ‘BARO’ or ‘TEMP COMP’, and press the ENT Key. Turn
the small FMS Knob to select the altitude, and press the ENT Key.
b) If ‘TEMP COMP’ was selected, the cursor moves to the temperature field. Turn the small FMS Knob to select the
temperature, and press the ENT Key.
Or: