CS 5000
User Manual
© 2009 GARRETT METAL DETECTORS 18 PN 1530100 REV H
6. SUPERVISOR ADJUSTMENTS
Several adjustments may be made at the Supervisor’s Level (Access Code #1). These are primarily
program/sensitivity settings and the operation of the IR Sensor. These supervisor’s adjustments can
be accessed only through use of a four-digit code (See instructions for altering Access Code #1 under
Installation Adjustments, Section 5.7)
To access the Supervisor Adjustment Mode for the first time, press the ACCESS touchpad and the
factory preset code of 1234. The factory default settings of PROG D SENS 160 will be displayed on
the LCD with the program designation blinking. Pressing the ACCESS touchpad will permit scrolling
through these selections.
For maximum security it is recommended that both Access Code numbers be changed from the fac-
tory default settings and that the numbers be known only to those who use them. Record the new
code numbers on the Access Settings card that accompanied this User’s Manual. It is also suggested
that codes be changed periodically, especially when any changes are made in personnel with access
to the codes.
6.1 PROGRAM
The programs detailed in Section 11 have been developed for use by the Garrett
CS 5000. These brief descriptions will give some indication of the intent of each program, but a final
judgment on the setting of each individual unit should be determined by the intent of its installation.
After the Program number is accessed through use of the four-digit code, + touchpad can be used to
increase the number, and the - touchpad to lower it. Press ACCESS for next adjustment or OPERATE
to return to normal operation.
6.2 SENSITIVITY
This option permits the unit to be adjusted (range of 1 to 200) to the proper level of
sensitivity within a chosen program. Press ACCESS until the SENS and the number are displayed on
the LCD. Use the + and - touchpads to adjust the number. Sensitivity of detection will be increased as
the number is made larger, allowing alarm responses on smaller targets.
After the desired Sensitivity number has been selected, press ACCESS for next adjustment or
OPERATE to return to normal operation.
6.3 IR ANALYSIS
The Garrett CS 5000 utilizes an Infrared Sensor to enhance the operation of the unit in special situ-
ations. IR Analysis — ON or OFF appears on the LCD to indicate whether or not the IR Analysis is
being used. The + or - touchpad is used to turn the IR Analysis off and on. Whenever this is done, it is
necessary to press ACCESS for the next adjustment or OPERATE to return to normal operation.
Utilization of the Infrared Sensor is not required for operation of the CS 5000 and may be disabled if
desired.
1. The units can operate more effectively by correlating signal responses with actual physical
movement. Because this sensor enables the Magnascanner to detect just those individuals and
objects while they are passing through the detector, it can minimize effects of noise and other
influences.
2. By inhibiting the alarm when no one is in its archway, the IR Analysis greatly minimizes nuisance
alarms. In instances where there is movement of large metal objects near the exterior of the unit,