EasyManua.ls Logo

Garrett CS 5000 - Ac & DC Control

Garrett CS 5000
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CS 5000
User Manual
©2009 GARRETT METAL DETECTORS 39 PN 1530100 REV H

•Disconnectunitsfrompowerline;
•OpenAccessDoorofDetectionUnit;
•Removethree(3)screwsthatholdcontrollercover;
•Usesynchronizationwire(18to24-gauge,2conductor)betweenunits;connectasshown;
•SettheendunittoMASTERCHANNELAandensurethatthisunitisconnectedtoeitherAC
powerorbatterypoweratalltimes;
•Replacecoversandreconnectpower;
•SetallotherunitstoSlave;
•RepeatpatternofCHANNELSA,C,andDforanyadditionalunits.
11.4 AC & DC CONTROL
11.4.1 AC CONTROL
Connection of an external alarm, locking device or other component may be made as shown below.
The optically-isolated triac output will conduct only during the time that the Red ALARM light is illu-
minated. It is recommended that the control not exceed 48Vrms and 100mA. The output is electri-
cally isolated from ground.
•OpenAccessDoorofdetectionunit;
•Removethree(3)screwsthatholdcontrollercover;
•Connecttherelayordevicetocontrol;
•Replacecoverandreconnectpower.
11.4.2 DC CONTROL
The three drawings that follow illustrate alternate methods of connecting an external device which
has requirements of low voltage direct current. The output is an open collector configuration capable
of switching 15V at 100mA or less, which includes connections to computing devices and other
equipment requiring low level DC.

Related product manuals