8.2.6 High Frequency Board
1. Remove upper capacitor bank assembly in accordance with instructions.
2. Disconnect cable from connector MK100 on high frequency board.
3. Remove two screws (T25) from high frequency board.
4. Remove one nut (8mm) from high frequency board standoff and remove board.
Reassembly is done in reverse order.
1
2
3
130BX258.10
1 T25 screw (step 3) 3 8mm retaining nut (step 4)
2 High frequency board
High Power Service Manual for Unit Sizes 6x