EasyManua.ls Logo

GE AF-650 GP - Page 132

GE AF-650 GP
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pin No. Schematic
Acronym
Function Description Reading Using a Digital Voltmeter
1 IU1 Current sensed,
U phase, not condi-
tioned
Approx 400 mv RMS @100% load
.937 VACpeak @ 165% of CT current rating. AC
waveform @ output frequency of the frequency
converter.
2 IV1 Current sensed,
V phase, not conditioned
Approx 400 mv RMS @100% load
.937 VACpeak @ 165% of CT current rating. AC
waveform @ output frequency of the frequency
converter.
3 IW1 Current sensed,
W phase, not condi-
tioned
Approx 400 mv RMS @100% load
.937 VACpeak @ 165% of CT current rating. AC
waveform @ output frequency of the frequency
converter.
4 COMMON Logic common This common is for all signals.
5 AMBT Ambient temp. Used to control FAN high and low fan speeds. 1 VDC approximately equal to 25C
6 FANO Control Card signal Signal from the control card to turn the fans on and off. 0 VDC ON command
5 VDC – OFF command
7 INRUSH Control Card signal Signal from the control card to start gating the SCR
front end
3.3 VDC – SCRs disabled
0 VDC – SCRs enabled
8 RL1 Control Card signal Signal from Control Card to provide status of Relay 01 0 VDC – Relay active
0.7 VDC – inactive
9 Not used
10 Not used
11 VPOS +18 VDC regulated sup-
ply +16.5 to 19.5 VDC
The red LED indicates voltage is present between VPOS
and VNEG terminals.
+18 VDC regulated supply +16.5 to 19.5 VDC
12 VNEG -18 VDC regulated sup-
ply
-16.5 to 19.5 VDC
The red LED indicates voltage is present between VPOS
and VNEG terminals.
-18 VDC regulated supply
-16.5 to 19.5 VDC
13 DBGATE Brake IGBT gate pulse
train
Varies w/ brake duty cycle
Voltage drops to zero when brake is turned off. Volt-
age increases to 4.04 VDC as brake duty cycle rea-
ches max.
14 BRT_ON Brake IGBT 5V logic level
signal.
Varies w/ brake duty cycle
5.10 VDC level with the brake turned off. Voltage
decreases to zero as brake duty cycle reaches max.
15 Not used
16 FAN_TST Control signal for fans Indicates Fan Test switch is activated to force the fans
on high
+5VDC – disabled
0VDC – fans on high
17 FAN_ON Pulse train to gate SCR’s
for fan voltage control.
In sync with line freq.
7 trigger pulses at 3Khz
5VDC - fans off
High Power Service Manual for Unit Sizes 6x
131
10

Table of Contents