Troubleshooti ng ti ps...s_t_ _ _o_y_R_ th_ch_rtb_/o__,rst_ yo__y_ot_ toc_//_ors_r_c_.
Problem Possible Causes What ToDo
Dehumidifier The dehumidifier Hake sure the dehumidifier's plug is pushed completely
doesnotstart isunplugged, into the outlet.
The fuse isblown/circuit , Checkthe housefuse/circuit breaker box and replace
breaker istripped, the fuse or resetthe breaker.
Dehumidifier has reached its The dehumidifier automatically turns off when either
preset level or bucket is full. condition occurs. Change to a lower setting or empty
the bucket and replace properly.
Bucket is not in the The bucket must be in place and securelyseated for the
proper position, dehumidifier to operate.
Power failure. There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. Forthis
reason,the unit may not start normal dehumidifying
for 3 minutes after it is turned back on.
Dehumidifierdoesnot Did not allow enough time ,,When first installed, allow at least 24 hours to maintain
drytheair as#should to remove the moisture, the desireddryness.
Airflow isrestricted. Hake sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidifier. Seethe
Choosinga Locationsection.
Dirty filter. Seethe Careand Cleaningsection.
The Humidity Control may For drier air, pressthe T pad and set to a lower percent
not be set low enough, value (%)or at CO(continuous)for maximum
dehumidification.
Doors end windows may not Checkthat all doors, windows and other openings
be closed tightly, are securelyclosed.
Clothes dryer may be , Installthe dehumidifier away from the dryer.
blowing moisture-laden Thedryer should be vented to the outside.
air into the room.
Room temperature Hoisture removal is best at higher room temperatures.
is too low. Lower room temperatures will reduce the moisture
removal rate. Hodels are designed to be operated at
temperatures above 4!°F (5°C).
Dehumidifier runs Area to be dehumidified * Thecapacity of your dehumidifier may not be adequate.
toomuch istoo large.
Doors and windows are open. * Closeall doors and windows to the outside.
Frostappearson Dehumidifier has been turned * This is normal. Frostwill usually disappear
the coils on recently, or room temperature within 60 minutes. Seethe Automatic Defrostsection.
isbelow 41°F(5°C).
Controls cannot be set
Fannoise
The compressor will turn off
and the fan will automatically
continue to run for
approximately 3 minutes at o
fixed setting.
Air is moving through
the dehumidifier.
This isnormal. Wait approximately 3 minutes and set the
fan as desired.
* This is normal.
10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE APEL70 and is the answer not in the manual?