About the controls on the dehumidifier.
HighandLow
fan indicator
lights
Cleanthe Filter Continuousoperationon
indicatorlight indicatorlight
[] High
Internal
•Pump On [] Low
Humiditg %
Continuous Bucket Full
!_ Power On
Clean the Filter Power On indicatorlight
Reset
Clee ing
BucketFulllightindicates
bucketneedstobeemptied
orisnotinplaceinthe unit
Controls
Whenthe bucket isfull or removed, the controls cannot beNOTE:
set.
Power Pad
Pressto turn the dehumidifier on and off.
Filter Timer
After 250 hoursof operation,the Clean the Filter indicator
lightwill glow to remind you to clean the filter.Removethe
filter and clean it.
Pressto turn off the Clean the Filter light. Seethe Care and
Cleaning section.
When you first usethe dehumidifier, set the humidity control
to 45% or 50%. Allow at least 24 hours for the dehumidifier
to achieve the humidity level.Ifyou still have damper air
than desired,set the humidity levelto a lower setting or
select Continuousfor maximum dehumidification.
Display
Shows the set % humidity level while setting, then shows
the actual (+/- 5% accuracy) room % humidity level.
Fan Speed Pad
Controls the fan speed.
Pressto select either High or Low fan speed.
Humidity Set Control Pads
Thehumidity levelcan be set within a range of 35%
RH(RelativeHumidity)to 80% RH(RelativeHumidity)in
5% increments or at COfor continuous operation. Toset
the unit for continuous operation, pressthe - pad until the
screen readsCO.
NOTE: IfCO (Continuous)isselected,the dehumidifier will
operate continuously at its maximum dehumidification
settings if attached to a hoseto drain or until the bucket is
full.
Fordrier air,press the - pad and set to a lower percent
value (%).
Fordamper air,pressthe + pad and set to a higher percent
value (%).
Other Features
Setthe fan control to High for maximum moisture
removal. When the humidity has been reduced and quiet
operation is preferred, set the fan control to Low.
Pump On/Off
Activates the internal pump function.
Pressfor 3 seconds to active the internal pump for
automatic removal of condensate. The Internal Pump On
indicator light will flash then remain illuminated once the
3 seconds are complete.
Pressto deactivate the pump.
BUCKETFULLLight
Glows when the bucket is ready to be emptied, or when the bucket
is removed or not replaced in the proper position.
Alarm
Ifthe bucket isfullor missingfor more than 3 minutes,an alarm will
soundfor about 10secondsto remindyou to emptyand replacethe
bucket.
Auto Shut Off
TheWater LevelControl Switch shuts off the dehumidifier when the
bucket isfull, or when the bucket is removed or not replaced in the
proper position. NOTE: Fanwill continue to run approximately 3
minutes after bucket is removed.
Auto Defrost
When frost buildsup on the evaporator coils,the compressor will
cycle off and the fan will continue to run until the frost disappears.
Power Outage
Inthe case of a power outage or interruption, the unit will
automatically restart, in the settings last used,after the power is
restored.