DigitalFlow™ Multipurpose Ultrasonic Liquid Flowmeter Startup Guide (1- and 2-Channel) 35
Chapter 3. Operation
3.3 Using the Display (cont.)
The middle portion of the screen pane is the prompt area. This area displays data, graphs, and logs in measurement
mode and menu prompts in programming mode. In addition, error code messages, which are described in the Service
Manual, are displayed in the prompt area.
The lower portion of the screen pane is called the option bar. The option bar displays the functions assigned to the four
keys immediately below the display screen ([F1]-[F4] for the left pane and [F5]-[F8] for the right pane). Press a function
key to select the function listed in the option bar immediately above it. If more than four functions are available, a
pointer ( ) appears on the far right of the locator bar. Press the [ or [ keys to display the additional functions on
the option bar.
For information about other symbols and text that may appear on the display screen, refer to the Service Manual.
3.4 Taking Measurements
The Model DF868 is capable of displaying several different variables in a variety of formats. However, this manual
will only discuss the basic measurement displays in the default screen format. Refer to the Programming Manual for
instructions on setting up alternate screen displays and see the Service Manual for a discussion of the diagnostic
parameters listed under the DIAG option.
Note: This section assumes that the left pane of the display screen is currently active. However, the same instructions
apply equally to the right screen pane, when it is active. Just change the function keys from [F1]-[F4] to [F5]-[F8].
For a 2-channel Model DF868, the following initial screen appears immediately upon completion of the internal
checks. As an example, the display shows the measured velocity in ft/sec for Channel 1.
Ch1 Channel Label gSITE
To select a different channel display option, press [F1]-[F4] (or [ and [F1]). See
Table 13 for a complete description of the available options.
Ch1 Velocity Ft/s
6.95
(error codes appear here)
CH1 CH2 SUM DIF
Table 13: Channel Display Options
Option Bar Choice Description
[F1] = CH1 Channel 1
[F2] = CH2 Channel 2
[F3] = SUM (Channel 1) + (Channel 2)
[F4] = DIF (Channel 1) - (Channel 2)
[ + [F1] = AVE [(Channel 1) + (Channel 2)]/2

Table of Contents

Other manuals for GE DigitalFlow DF868

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE DigitalFlow DF868 and is the answer not in the manual?

GE DigitalFlow DF868 Specifications

General IconGeneral
BrandGE
ModelDigitalFlow DF868
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals