EasyManua.ls Logo

GE DigitalFlow GF868 - Chapter 4. Specifications; General Specifications; Hardware Configuration; Environmental

GE DigitalFlow GF868
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DigitalFlow™ GF868 Startup Guide (1 and 2-Channel) 41
Chapter 4. Specifications
Chapter 4. Specifications
4.1 General Specifications
The general specifications for the Model GF868 flowmeter are divided into the following categories:
4.1.1 Hardware Configuration
Package Options:
Epoxy-coated aluminum (standard)
Stainless steel (optional)
Fiberglass (optional)
Explosion-proof (optional)
Flameproof (optional)
Physical: (Epoxy-coated aluminum package)
Size: 14.24 11.4 5.12 in. (36.2 29 13 cm)
Weight: 11 lb (5 kg)
4.1.2 Environmental
Operating Temperature:
-4° to 131°F (–20° to 55°C)
Storage Temperature:
–67° to 167°F (–55° to 75°C)
4.1.3 Flow Accuracy (% of Reading)
Velocity Accuracy:
1-Path Measurement
2% to 5% of reading at ±1 to ±275 ft/s (±0.3 to ±85 m/s)
2-Path Measurement
1.4% to 3.5% of reading at ±1 to ±275 ft/s (±0.3 to ±85 m/s)
Note: Specifications assume a fully developed flow profile. This is installation-dependent and may require a straight
run of pipe 20 diameters upstream and 10 diameters downstream. Accuracy depends on whether measurement
is 1- or 2-path.
4.1.4 Range
Bi-directional:
–275 to –0.1 ft/s (–85 to –0.03 m/s)
+0.1 to 275 ft/s (0.03 to 85 m/s)