Chapter 2. Error Codes and Screen Messages
20 DigitalFlow™ GS868 Service Manual
2.11 E9: Press In
Problem: This message indicates a pressure input error.
Cause: The pressure exceeds the specified limits for the analog inputs option card or no input device is connected.
Action: Check the pressure transmitter and the connecting cable. Refer to Chapter 1, Calibration, and recalibrate
the analog inputs on the option card.
2.12 E10: Special Input
Problem: This message indicates a special input error.
Cause: The special input exceeds the specified limits for the analog inputs option card.
Action: Check the special transmitter and the connecting cable. Refer to Chapter 1, Calibration, and recalibrate the
analog inputs on the option card.
2.13 E11: Super Saturated
Problem: This message indicates that, based on the temperature and pressure readings, the steam is super saturated
and may become two-phase.
Cause: Low temperature in the system.
Action: Raise the system temperature or lower the system pressure until all the water vaporizes.
2.14 E12: Low Pressure
Problem: This message indicates the pressure reading has dropped below the programmed PRESSURE LIMIT.
Cause: System shutdown or a faulty pressure transmitter.
Action: Bring the steam system back online, or check and recalibrate the pressure transmitter.
2.15 E13: Over Range
Problem: This error code message indicates that the present measurement exceeds the capacity of the meter.
Cause: A internal mathematical overflow has occurred in either the volumetric or mass flow calculations.
Action: Select larger measurement units or a shorter time interval for the current measurement parameter. For
example, choose
KSCF/M instead of SCF/M in the SYSTM menu. See Chapter 2, Initial Setup, of the Startup
Guide for instructions.