Diagnostics From The Board
Recirculation Pump
Disconnect power to the washer.
Access the control.
Disconnect the J701 connecter.
Check the resistance from the BROWN
WIRE to the neutral WHITE WIRE at
the J101 connecter. Should read
approximately 30.5 OHM.
If Resistance is good, check for 120vac
at the same locations.