CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOL
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 18–7
00F0 Port 1: Number of late collisions
occurred
0 to
4294967295
1F9 0
00F2 Port 1: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
00F4 Port 1: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
00F6 Port 1: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
00F8 Port 1: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
00FA Port 1: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
00FC Port 1: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
00FE Port 1: Number of MAC error packets 0 to
4294967295
1F9 0
0100 Port 1: Number of dropped received
packets
0 to
4294967295
1F9 0
0102 Port 1: Number of multicast frames
sent
0 to
4294967295
1F9 0
0104 Port 1: Number of broadcast frames
sent
0 to
4294967295
1F9 0
0106 Port 1: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
0108 Port 2: Number of bytes received 0 to
4294967295
1F9 0
010A Port 2: Number of bytes sent 0 to
4294967295
1F9 0
010C Port 2: Number of frames received 0 to
4294967295
1F9 0
010E Port 2: Number of frames sent 0 to
4294967295
1F9 0
0110 Port 2: Total bytes received 0 to
4294967295
1F9 0
0112 Port 2: Total frames received 0 to
4294967295
1F9 0
0114 Port 2: Number of broadcast frames
received
0 to
4294967295
1F9 0
0116 Port 2: Number of multicast frames
received
0 to
4294967295
1F9 0
0118 Port 2: Number of frames with CRC
error
0 to
4294967295
1F9 0
011A Port 2: Number of oversized frames
received
0 to
4294967295
1F9 0
011C Port 2: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
011E Port 2: Number of jabber frames
received
0 to
4294967295
1F9 0
0120 Port 2: Number of collisions occurred 0 to
4294967295
1F9 0
0122 Port 2: Number of late collisions
occurred
0 to
4294967295
1F9 0
0124 Port 2: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
0126 Port 2: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 5 of 33)
Address Description Range Step Format Default

Table of Contents

Other manuals for GE MultiLink ML1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1600 and is the answer not in the manual?

GE MultiLink ML1600 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1600
CategorySwitch
LanguageEnglish

Related product manuals