EasyManuals Logo

GE MultiLink ML1600 User Manual

GE MultiLink ML1600
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #301 background imageLoading...
Page #301 background image
CHAPTER 18: MODBUS PROTOCOL MODBUS PROTOCOL
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL 18–17
0320 Port 12: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
0322 Port 12: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
0324 Port 12: Number of MAC error packets 0 to
4294967295
1F9 0
0326 Port 12: Number of dropped received
packets
0 to
4294967295
1F9 0
0328 Port 12: Number of multicast frames
sent
0 to
4294967295
1F9 0
032A Port 12: Number of broadcast frames
sent
0 to
4294967295
1F9 0
032C Port 12: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
032E Port 13: Number of bytes received 0 to
4294967295
1F9 0
0330 Port 13: Number of bytes sent 0 to
4294967295
1F9 0
0332 Port 13: Number of frames received 0 to
4294967295
1F9 0
0334 Port 13: Number of frames sent 0 to
4294967295
1F9 0
0336 Port 13: Total bytes received 0 to
4294967295
1F9 0
0338 Port 13: Total frames received 0 to
4294967295
1F9 0
033A Port 13: Number of broadcast frames
received
0 to
4294967295
1F9 0
033C Port 13: Number of multicast frames
received
0 to
4294967295
1F9 0
033E Port 13: Number of frames with CRC
error
0 to
4294967295
1F9 0
0340 Port 13: Number of oversized frames
received
0 to
4294967295
1F9 0
0342 Port 13: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
0344 Port 13: Number of jabber frames
received
0 to
4294967295
1F9 0
0346 Port 13: Number of collisions occurred 0 to
4294967295
1F9 0
0348 Port 13: Number of late collisions
occurred
0 to
4294967295
1F9 0
034A Port 13: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
034C Port 13: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
034E Port 13: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
0350 Port 13: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
0352 Port 13: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
0354 Port 13: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
0356 Port 13: Number of MAC error packets 0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 15 of 33)
Address Description Range Step Format Default

Table of Contents

Other manuals for GE MultiLink ML1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1600 and is the answer not in the manual?

GE MultiLink ML1600 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1600
CategorySwitch
LanguageEnglish

Related product manuals