Page 31
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
27 19 ZONES 9-16, ZONE TYPES 6-6-6-6-6-6-6-6 __ __ __ __ __ __ __ __
ZONES 9-16, PARTITION SELECTION (Segment 1=Zone 9 thru Segment 8=Zone 16) 28 19
Segment #1
1 - Partition #1
2 - Partition #2
Segment # 2
1 - Partition #1
2 - Partition #2
Segment #3
1 - Partition #1
2 - Partition #2
Segment #4
1 - Partition #1
2 - Partition #2
Segment #5
1 - Partition #1
2 - Partition #2
Segment #6
1 - Partition #1
2 - Partition #2
Segment #7
1 - Partition #1
2 - Partition #2
Segment #8
1 - Partition #1
2 - Partition #2
SIREN AND SYSTEM SUPERVISION
Segment #1
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Siren sounds for telephone line cut while armed
Siren sounds for telephone line cut while disarmed
Siren blast at arming
Siren blast at exit delay expiration
Siren blast at closing kissoff
Siren sounds during a cross zone verification time
Siren sounds for a tamper
Siren blast one time for keyswitch arming, two times for disarming
(NOTE: This feature must be disabled for SIA
CP-01 installations.)
Segment #2
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Convert siren driver to voltage out
Siren sounds for expander trouble (required for U.L.)
Immediate restore by zone
Dynamic battery test performed upon arming
Battery missing test performed every 12 seconds
Manual bell test performed during [r]-[4] test function
Manual communicator test performed during [r]-[4] test function
Box tamper enabled.
Segment #3
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Box Tamper report enabled
AC Fail report enabled
Low Battery report enabled
Auxiliary power over current report enabled
Siren supervision report enabled
Telephone Line Cut report enabled
Reserved.
Expander trouble report enabled
Segment #4
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Failure To Communicate report enabled
Log Full report enabled
Autotest report enabled
Start and End Programming report enabled
End Download report enabled
Sensor Low Battery report enabled
Sensor Missing report enabled
Reserved.
Segment #5
37 19
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Lost Clock service LED enable
Enables Zone Doubling for zones 7-12 (requires NX-200 Zone Doubling Kit)
Disables on-board zones
Enables two trips on the same cross-zone to activate the alarm
Disables bypass reports for force armed zones
Reserved
Clock uses internal crystal
Disable Temporal Siren on Fire (must NOT disable for UL systems)
38 20
SWINGER SHUTDOWN COUNT
1 _

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6 and is the answer not in the manual?

GE NetworX NX-6 Specifications

Operating Power IconOperating Power
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Loop Specifications IconLoop Specifications
loop resistance for standard loop300 Ohms Maximum
loop resistance for 2-wire smokes30 Ohms Maximum
loop response500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
LED Keypad Specifications IconLED Keypad Specifications
led keypad current draw130 mA max.
led keypad dimensions width6.4"
led keypad dimensions height4.0"
led keypad dimensions depth1.1"
NX-148E LCD Keypad Specifications IconNX-148E LCD Keypad Specifications
nx-148e lcd keypad current draw110 mA max.
nx-148e lcd keypad dimensions width6.4"
nx-148e lcd keypad dimensions height5.3"
nx-148e lcd keypad dimensions depth1.0"
Enclosure and Shipping IconEnclosure and Shipping
metal enclosure dimension width11.25"
metal enclosure dimension height11.25"
metal enclosure dimension depth3.50"
shipping weight9 lbs.