LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA
27 19 ZONES 9-16, ZONE TYPES 6-6-6-6-6-6-6-6 __ __ __ __ __ __ __ __
ZONES 9-16, PARTITION SELECTION (Segment 1=Zone 9 thru Segment 8=Zone 16) 28 19
Segment #1
1 - Partition #1
2 - Partition #2
Segment # 2
1 - Partition #1
2 - Partition #2
Segment #3
1 - Partition #1
2 - Partition #2
Segment #4
1 - Partition #1
2 - Partition #2
Segment #5
1 - Partition #1
2 - Partition #2
Segment #6
1 - Partition #1
2 - Partition #2
Segment #7
1 - Partition #1
2 - Partition #2
Segment #8
1 - Partition #1
2 - Partition #2
SIREN AND SYSTEM SUPERVISION
Segment #1
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Siren sounds for telephone line cut while armed
Siren sounds for telephone line cut while disarmed
Siren blast at arming
Siren blast at exit delay expiration
Siren blast at closing kissoff
Siren sounds during a cross zone verification time
Siren sounds for a tamper
Siren blast one time for keyswitch arming, two times for disarming
(NOTE: This feature must be disabled for SIA
CP-01 installations.)
Segment #2
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Convert siren driver to voltage out
Siren sounds for expander trouble (required for U.L.)
Immediate restore by zone
Dynamic battery test performed upon arming
Battery missing test performed every 12 seconds
Manual bell test performed during [r]-[4] test function
Manual communicator test performed during [r]-[4] test function
Box tamper enabled.
Segment #3
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Box Tamper report enabled
AC Fail report enabled
Low Battery report enabled
Auxiliary power over current report enabled
Siren supervision report enabled
Telephone Line Cut report enabled
Reserved.
Expander trouble report enabled
Segment #4
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Failure To Communicate report enabled
Log Full report enabled
Autotest report enabled
Start and End Programming report enabled
End Download report enabled
Sensor Low Battery report enabled
Sensor Missing report enabled
Reserved.
Segment #5
37 19
1 -
2 -
3 -
4 -
5 -
6 -
7 -
8 -
Lost Clock service LED enable
Enables Zone Doubling for zones 7-12 (requires NX-200 Zone Doubling Kit)
Disables on-board zones
Enables two trips on the same cross-zone to activate the alarm
Disables bypass reports for force armed zones
Reserved
Clock uses internal crystal
Disable Temporal Siren on Fire (must NOT disable for UL systems)
38 20
SWINGER SHUTDOWN COUNT
1 _