NX-6V2 Control
L 25 ZONES 1-8 ZONE TYPE 8 ............ numerical
Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8. Default Zone Types are
found in the table on page 16. To customize a Zone Type, see page 25.
26 PARTITION SELECT, ZONES 1-8 8 ............ feature select
Location 26 is used to select the partition(s) that zones 1 - 8 reside in. A zone may reside in any combination of the 8 partitions. If a
burglary zone resides in more than 1 partition, it will only be active when all partitions it resides in are armed. A zone that
resides in more than 1 partition will be reported to its lowest partition number. Location 26 has 8 segments. Segment 1
corresponds to zone 1, and Segment 8 corresponds to zone 8.
Segments 1 - 8:
1 = Partition 1 2 = Partition 2
L 27 ZONES 9-16 ZONE TYPE 8 ............ numerical
Location 27 contains the Zone Type for zones 9 -16. Segment 1 is for zone 9; Segment 8 is for zone 16. Default Zone Types are
found in the table on page 16. To customize a Zone Type, see page 25.
28 PARTITION SELECT, ZONES 9-16 8 ............ feature select
Location 28 is used to select the partition(s) that zones 9-16 reside in. A zone may reside in any combination of the 8 partitions. If a
burglary zone resides in more than 1 partition, it will only be active when all partitions are armed. A zone that resides in more
than 1 partition will be reported to its lowest partition. Location 28 has 8 segments. Segment 1 corresponds to zone 9 and
Segment 8 corresponds to zone 16.
Segments 1 - 8:
1 = Partition 1 2 = Partition 2
29 - 36 RESERVED
L 37 SIREN AND SYSTEM SUPERVISION 7 ............ feature select
Location 37 is used to enable various system feature and reporting options. (For specific definitions, refer to the Glossary beginning on
page 39)
Segment 1:
1 = On if siren sounds for "Telephone Line Cut" when armed.
2 = On if siren sounds for "Telephone Line Cut" when disarmed.
3 = On if siren blast at arming.
4 = On if siren blast at exit expiration.
5 = On if siren blast at closing kissoff.
6 = On if siren sounds during a "Cross Zone" verification time.
7 = On if siren sounds for a Zone or Box Tamper.
8 = On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming. (Note: Must be disabled for SIA CP-01 installations.)
Segment 2:
1 = On if siren driver should be a voltage output. Off if on board siren driver enabled.
2 = On if siren sounds for expander trouble (required for UL installations).
3 = On for Immediate Restore by zone. Off for zones to restore only when siren is off.
4 = On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See location 40)
5 = On if Battery Missing Test is performed every 12 seconds.
6 = On if Manual Bell Test performed during [r]-[4]-[4] test function.
7 = On if Manual Communicator Test performed during [r]-[4]-[4] test function.
8 = On if Box Tamper terminals on the control panel are enabled.
Segment 3:
1 = On if Box Tamper report enabled.
2 = On if AC Fail reporting enabled.
3 = On if Low Battery reporting enabled.
4 = On if Aux. Power Overcurrent report enabled.
5 = On if Siren Supervision report enabled.
6 = On if Telephone Line Cut report enabled.
7 = On if Ground Fault Detection report enabled.
8 = On if Expander Trouble reporting enabled.