EasyManua.ls Logo

GE NetworX NX-6V2 - Special Features Configuration; Go To Program Code Setup; Auxiliary Output Partition Selection

GE NetworX NX-6V2
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
NX-6V2 Control
Segment 9 - Fire Alarm Verification time in seconds 120-255 seconds .................................... (0 = no fire alarm verification)
NOTE: The fire alarm verification feature is not approved for residential use in California
Segment 10 - Listen-In time in seconds 0-255............................................................................ (0 = no Listen-In time)
Segment 11 - Zone Activity Monitor feature timed in days 0 – 255 ............................................. (0 = disabled)
Segments 12-14 Reserved.
41 SPECIAL FEATURES 1 ............ feature select
Segment 1:
1 = On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To Program Code" are 6
digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-DIGIT CODE
BEFORE EXITING PROGRAMMING.
2 = On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming call for download)
functions.
3 = Enable Auto Cancel / Abort (Refer to Glossary beginning on page 39)
4 = Enable Walk-Test Mode (Refer to Glossary beginning on page 39)
5 = On enables Auto Force-Arming with keyfob or keyswitch.
6 = Reserved.
7 = Reserved.
8 = Reserved. (Do not program!)
L 42 GO TO PROGRAM CODE 6 ............ numerical
Location 42 contains the "Go To Program Code". This location contains either a 4 or 6-digit code. If the 6-digit code option is enabled
in Location 41, THIS CODE MUST CONTAIN SIX (6) DIGITS. If this option is not enabled in location 41, the last 2 segments (digits)
will be ignored. With the NX-6V2 disarmed, the "Go To Program Code" can be used to enter the Program Mode.
43 GO TO PROGRAM CODE PARTITION & AUTHORIZATION 2 ............ feature select
The "Go To Program Code" can be used as a standard arm/disarm code. When using the code to arm or disarm, the user ID is 255.
(This code may not be changed in the Run Mode.)
Segment 1:
1 = Reserved.
2 = On enables "Go To Program Code" as an arm only code.
3 = On enables "Go To Program Code" as an arm only after closing.
4 = On enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = On enables "Go To Program Code" as an arm/disarm code.
6 = On enables "Go To Program Code" to bypass zones.
7 = On enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2:
1 = On enables the "Go To Program Code" for Partition #1.
2 = On enables the "Go To Program Code" for Partition #2.
3-8 = Reserved.
L 44 DURESS CODE 6 ............ numerical
Location 44 contains the "Duress" code. This Location contains either 4 or 6 digits. If the 6-digit code option is enabled in Location 41,
THIS CODE MUST CONTAIN SIX (6) DIGITS. If the 6-digit option is not enabled in location 41, the last 2 digits will be ignored. If the
duress code is programmed, it will work for all partitions.
45 AUXILIARY OUTPUT 1-4 PARTITION SELECTION 4 ............ feature select
Location 45 is used to select which partition(s) the events must occur in before the output will activate. Location 45 has 4 segments.
Segment 1 corresponds to output 1, and Segment 4 corresponds to output 4.
Segment 1 (Aux 1) Segment 2 (Aux 2) Segment 3 (Aux 3) Segment 4 (Aux 4)
1= Partition 1 1= Partition 1 1= Partition 1 1= Partition 1
2= Partition 2 2= Partition 2 2= Partition 2 2= Partition 2

Related product manuals