NX-6V2 Control 29
166 ZONE TYPE 29 ALARM EVENT CODE 1............. numerical
Location 166 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 43. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 25 for details.
167 ZONE TYPE 29 CHARACTERISTIC SELECT 5............. feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 25
168 ZONE TYPE 30 ALARM EVENT CODE 1............. numerical
Location 168 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 43. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 25 for details.
169 ZONE TYPE 30 CHARACTERISTIC SELECT 5............. feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 25
170-205 RESERVED
206 AUTO DISARM DAY SELECTION 8............. feature select
Location 206 selects which days each partition will auto disarm. Segment 1 is for partition 1, and segment 2 is for partition 2. If a zone
is faulted when the panel tries to auto disarm, the zone will be bypassed.
Segments 1-2:
1 = Auto Disarming on Sunday.
2 = Auto Disarming on Monday.
3 = Auto Disarming on Tuesday.
4 = Auto Disarming on Wednesday.
5 = Auto Disarming on Thursday.
6 = Auto Disarming on Friday.
7 = Auto Disarming on Saturday.
8 = Reserved.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6V2 and is the answer not in the manual?

GE NetworX NX-6V2 Specifications

Power IconPower
operating power16.5 VAC 40, or 50 VA Transformer
auxiliary power with 25 VA Transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA Transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E Power Supply12 VDC Regulated 2 AMPS + Control Panel Power
Loop Specifications IconLoop Specifications
loop resistance standard loop300 Ohms Maximum
loop resistance 2-wire smokes30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Keypad Specifications IconKeypad Specifications
LED keypad current draw130 mA max.
LED keypad zones normal without sounder55 mA
LED keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
NX148E LCD keypad current draw110 mA max.
NX148E LCD keypad without sounder75 mA
NX148E LCD keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
Dimensions and Weight IconDimensions and Weight
metal enclosure dimension11.25" Wide, 11.25" High, 3.50" Deep
shipping weight9 lbs.