NX-148E LCD Code Pad Installation and Setup Manual
10
6e. Set Code Pad Options
Action Result

Prompts to ‘Please Enter Your Code’.
[program code]
The LCD will now prompt you through the options
listed on the following chart.
The current state of the option will be shown in
the lower right corner of the display.
Advances to the next option without making
changes.
Otherwise, follow the instructions on the bottom
line of the LCD display to select the desired
option. This will also advance to the next option.
OPT
Code Pad Features
1 Code Pad Tamper Enable code pad tamper
2 Silent Code Pad? Enable silent code pad option. If enabled, only the entry/exit and
sounder chime are silenced.
3 Ding Dong Chime? Enable ding dong sound for chime. If off, chime will be a single
tone. (Refer to NX-16 Alarm Panel Installation & Programming
manual, feature 25)
4 5 Sec. Silence? Enable key press silence option. Silences the pulsing code pad
sounder for 5 seconds when a key is pressed.
5 Armed Zone Info? Enable armed zone information. If on, the LCD code pad will
display faulted or bypassed zone information when the system is
armed.
6 Beep On Panics? Enable panic, fire, and medical beep tone. Will sound a short beep
to verify that the key press was accepted.
7 Disable Service? Suppresses the ‘Service’ message. This will not allow the ‘Service
Required’ message to be displayed for any reason. If there is a
system trouble,
will still show the ‘Service Required’ menu.
8 Master Code Pad? Enable multi-area mode
9 Custom Message? Enable custom message display
10 Clock? Enable clock display
11 Custom Msg. Lock? Enable custom message lock. Prevents over-writing the custom
message during code pad copy.
12 Select an option: Programs special characteristics.
1 = Display ‘Press For Help’
2 = Disable LED Extinguish on this code pad
3 = On if PIN should be hidden when programming
4 = On suppresses beeps when an RF transmission is lost
5-8 = Reserved (Do not program!)

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")