NX-148E LCD Code Pad Installation and Setup Manual 
16
7l.  Changing User Codes 
  For systems with areas - someone changing the code of another person must have access to all or 
more areas than the user being changed. 
 
Action    Result 
   
       
Prompts ‘Please Enter Your Code’. 
 [master code] 
       
Prompts for a user number. 
 [user code] 
 
       
Prompts for a new code. 
2-digit ID if NX-4, NX-8, NX-12, NX-16 
3-digit ID if NX16 (use leading zeros!!  i.e.  for 
user 7)
 
 [new user code] 
       
Prompts for a user number.  Repeat 3
rd
 and 4
th
 
steps if another user code needs to be 
programmed. 
  Code pad will beep 3 times if code is rejected.
 #  while display is prompting 
for a user number. 
       
Exits and saves data. 
 
 
7m. Assigning Authority Level 
 You must have authority to the area you wish to add or remove from another person’s authority. 
 
Action    Result 
   
       
Prompts ‘Please Enter Your Code’. 
 [master code] 
       
Prompts for a user number. 
 [user code]  
 
       
Prompts through the following list of attributes. 
2-digit ID if NX-4, NX-8, NX-12, NX-16 
3-digit ID if NX16 (use leading zeros!!  (i.e.  
for user 7) 
 
Outputs used?   
If NO…    If YES… 
Master code?    Output 4 enable? 
Sched arm only?    Output 3 enable? 
Arm only?    Output 2 enable? 
Reserved    Output 1 enable? 
  Open / Close Rprt?
 
 Bypass enable?   
 Arm / Disarm?