NX-8E CONTROL
14
number of attempts have been made to Phone #1. If a "2" is programmed in this segment, it will cause the NX-8E to
make the dial attempts in increments of two. The first two attempts will be made to Phone #1, the next two attempts to
Phone #2, then repeating until the total number of attempts designated in Segment 1 is completed.
REPORTING EVENTS TO PHONE NUMBER 1
Phone #1 has two programming locations that are used to select which events are reported to this phone number.
Location 4 is used to select which events are reported to Phone #1. Location 5 is used to select which partitions are
reported to Phone #1. If dual or split reporting is not desired, location 4 should be used to select all events to Phone
#1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired, and the split is based
on the event type (such as alarm, open/close, etc.), location 4 should be used to select only those events that should
be reported to Phone #1 and location 5 should be left at the factory default of "0". If dual or split reporting is desired,
and the split is based on partition, location 4 should be programmed as a "0" and location 5 should be used to select
those partitions that should be reported to Phone #1. If no events should be reported to Phone #1, both locations
should be programmed as "0" (disabling all options).
LOCATION 4 - EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection data)
Segment 1: 1 = Alarms and Alarm Restores.
2 = Opening and Closings.
3 = Zone Bypass and Bypass Restores.
4 = Zone Trouble and Trouble Restores.
5 = Power Fail, Low Battery, Power Restore, and Low Battery Restore.
6 = Bell Cut, Telephone Line Cut, Bell Cut Restore, Telephone Line Restore.
7 = Test Reports.
8 = Start and End programming, Download complete.
Segment 2: 1 = Zone and Box Tamper and Tamper Restore.
2 = Auxiliary Power Overcurrent, Ground Fault, and Restore for both.
3 = Wireless Sensor Missing and Restore.
4 = Wireless Sensor Low Battery and Restore.
5 = Expander Trouble and Restore.
6 = Fail To Communicate.
7 = Zone Activity Monitor.
8 = Reserved.
LOCATION 5 - PARTITIONS REPORTED TO PHONE #1 (1 segment, feature selection data)
Location 5 is used when events to be reported to a phone number are based upon the partition regardless of the
event. If this location is used, location 4 should be programmed as "0".
Segment 1: 1 = Partition #1
2 = Partition #2
3 = Partition #3
4 = Partition #4
5 = Partition #5
6 = Partition #6
7 = Partition #7
8 = Partition #8
L LOCATION 6 - PROGRAMMING PHONE #2 (20 segments, numerical data)
Phone #2 is programmed in location 6. A "14" indicates the end of the phone number. Delays of four seconds can be
programmed at any point in the phone number by programming a "13" in the appropriate segment. If tone dialing is
desired, program a "15" in the segment where tone dialing should begin. If the entire number should be tone dialing,
program a "15" in the first segment. Program an A11" for a Ar@, and a A12" for a A#@.
L LOCATION 7 - ACCOUNT CODE FOR THE PHONE #2 (6 segments of numerical data)
The account code sent when Phone #2 is dialed is programmed in location 7. Program a A10" in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6 segments. If
this location is left unprogrammed, account code 1 will be used when the second phone number is dialed.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")