NX-8E CONTROL
5
Code Required Options
- The NX-8E can be programmed to require a code for bypassing zones and/or initiating a
download using the [r]-[9]-[8] or [r]-[9]-[9] function. (See locations 23 and 41, pages 18 and 23)
Communication Formats
- The NX-8E can report in multiple formats. It is recommended that you use Contact ID or
SIA formats if possible. If you wish to report to a pager or in a 4+2 format to a central station, you must program each
code to be reported. (See locations 56-83 and 111-169, pages 27-29 and 33-37)
Cross Zoning
- This feature requires two or more trips on a zone or zones programmed as "cross zones" within a
specified time before reporting an alarm. During the time between trips, the NX-8E can be programmed to sound the
keypad and/or the siren. The NX-8E can also be programmed to report an alarm after two or more trips on the same
zone. (See locations 37, 39, 40 and 110-149, pages 22, 23, 33-37)
Dual / Split / Multiple Reports
- The NX-8E can send communication reports to three different phone numbers for
dual, split or multiple reports selectable by event or partition. (See locations 4, 10, and 16, pages 14, 15, 17)
Duress Code
- If a duress code is programmed the NX-8E will send a duress signal whenever the panel is armed or
disarmed with this code. If open/close reports are sent, the user code will be 254. (See location 44, page 24)
Dynamic Battery Test
- The NX-8E can be programmed to perform a Dynamic Battery Test for a selected duration
the first time the panel is armed or disarmed every day, as well as by pressing [r][4] Test Function. If the panel is not
armed or disarmed during the day, it will perform the test at midnight. The NX-8E can also be programmed to perform
a missing battery test every 12 seconds. (See locations 37 and 40, pages 22 and 23)
Early to Open / Late to Close
If an opening occurs before the opening and closing times, the NX-8E will send an
“Early Open” report. If it fails to close on or before the designated closing time, the NX-8E will send a “Late to Close”
report.
End of Line Resistor Defeat
The NX-8E can be programmed to make zones 1-8 for normally closed operation only,
eliminating the need for the end of line resistors on these zones. When a zone is programmed for normally closed
operation, a short on that zone will not change the loop condition, and an open on that zone will produce a faulted
condition. This feature will be ignored by any Priority zone. (See locations 111-169, pages 33-37) NOTE: For UL
installations, all zones must be programmed as supervised.
Entry-Guard
- This unique low level arming mode has been developed to reduce the most common source of false
alarms. When armed with the AInstant@ LED on, the opening of any zones designated as "Entry Guard zone" will
initiate the keypad sounder and start the entry delay before creating an alarm. All other zones will function as normal.
This arming mode will encourage system owners to use their system more frequently when the premises are
occupied. (See locations 111-169, pages 33-37) NOTE: For UL installations, this feature shall be disabled.
Exit Error
- If enabled, the NX-8E will send an "Exit Error Report" if an entry/exit zone is faulted at the instant the exit
delay expires. This report will be sent along with the user number that armed the system, if the panel is not disarmed
before the entry delay expires. The alarm report will also be sent. Even if this feature is not enabled, the siren will
sound if any entry/exit zone is faulted at the instant the exit delay expires. (See location 23, page 18)
Expander Trouble
- The NX-8E will report expander trouble to the central station if enabled. This condition will
illuminate the "Service" LED on the keypad even if not reported. NOTE: The keypads are considered expanders. The
number of the expansion devices reported can be found on page 53. (See location 37, page 22)
Fail to Communicate
- The NX-8E will illuminate the "Service" LED if a report fails to reach the central station. If
enabled, when the next report is successfully communicated, a Fail to Communicate code will be reported. (See
location 37, page 22)
Fire Alarm Verification
- When enabled, the NX-8E will verify a Fire alarm by requiring more than one trip on a
smoke detector within a specified time before creating an alarm. (See location 40, page 23) This feature is not
approved for residential use in California.
Force Arming
- When enabled, the NX-8E can be Force Armed with zones violated. Under this condition, if a force
armable zone is not secure, the "Ready" LED will flash. At the end of the exit delay, these zones will become
bypassed. If these zones become secured any time during the arming cycle, they will be unbypassed and active in the
system. If "Bypass Report" is enabled, the force arming zones can be programmed to report bypass when they are
Force Armed (default), or to not report bypass even if "Bypass Report" is enabled. (See locations 37, and 111-169,
pages 22 & 33-37) NOTE: For UL installations, this feature shall be disabled.
Ground Fault
- If the NX-870 is used, a fault of the earth ground can be reported to the central station. If it is not
reported, this condition will illuminate the "Service" LED on the keypad. (See location 37, page 18)

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")